User manual

Technical Features
Quick Reference Guide 19
Technical Features
*Having a switching regulator inside, the BC-80X0 draws the same power, regardless of the
supply voltage. In other words, as the input voltage increases the current drawn decreases.
BC-80X0
Electrical Features
Supply Voltage
External Power 10..30 VDC
Host Power 5 VDC ±10%
Power Consumption
External Power max. 10 W (charging) *
Host Power max. 500 mA (charging)
Indicators
Ext. Power/Data yellow LED
Host Power/Data yellow LED
Reader batt. state green/red LED
Spare batt. state green/red LED (BC-8060 only)
beeper
Time of Recharge
External Power max. 4 hours with 2150 mAh Li-Ion battery
Host Power max. 10 hours with 2150 mAh Li-Ion battery
Radio Features
European Models USA Models
Radio frequency 433.92 MHz 910 MHz
Bit Rate 19200 baud 36800 baud
Range (in open air) 50 m 30 m
Environmental Features
Working Temperature
Radio -20° to +50 °C / -4° to +122 °F
Battery Charging 0° to +40 °C / +32° to +104 °F
Storage Temperature -20° to +70 °C / -4° to +158 °F
Humidity 90 % non condensing
Protection Class IP40
Mechanical Features
Weight without mount-
ing base
about 380 g / 13.4 oz
Dimensions (without
antenna)
240 x 108 x 95 mm / 9.44 x 4.25 x 3.74 in
Material ABS
System Configuration BC-80X0 STARGATE™
Max number of devices per base
station
32 255
Max number of devices in the same
reading area
2000
Max number of base stations in
network
16 (including cradle Master)