User manual

Chapter 6: Tekterm Application
Serial
284
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
6.19.1.6 Serial
Primary Port & Secondary Port
ANSI print commands (such as ‘MC’ or Media Copy) control the transfer of data to
and from the serial and console ports on the hand-held. At the 7535/7530, the value
assigned at the ‘Primary Port’ and ‘Secondary Port’ parameters determines which
port the ANSI print command will identify and use as primary and secondary. The
allowable options are: Any Available, Ist printer, 2nd printer, 3rd printer, 4th printer,
1st Serial, 2nd Serial, 3rd Serial, 4th Serial and Disabled.
Async In
When this parameter is enabled (set to “Y”), the serial (async) port is ready to
receive input at all times.
Start/End
These parameters specify the “start” and “end” characters of input received from
the serial (async) port.
6.19.1.7 Host Char Set
The ‘Host Char Set’ menu allows you to specify a character set in the ‘Lower’ and
‘Upper’ character tables.
Note: When an 8-bit set is selected from the ‘Lower’ character set, the ‘Upper
character set will change to the same value. The ‘Upper’ character set
cannot be altered until a non-8-bit value is assigned for the ‘Lower’
character set.
To choose ‘Lower’ and ‘Upper’ character sets:
Position the cursor on the ‘Lower’ or ‘Upper’ parameter, and press the
<RIGHT> or <LEFT> arrow key to display the character set options.
Primary Port Any Available see text
Secondary Port Any Available see text
Async In N Y/N
Start 0 0..255
End 0 0..255
05
Serial
Range
Lower ASCII ISO-IR 006
Upper DEC Multinational
Host Char Set
05