Psion Teklogix 7535/7530 Hand-Held Computer User Manual 269
Chapter 6: Tekterm Application
Host Conn
Other applications running in the 7535/7530, such as a TESS session or another
ANSI session must each have a different number. In addition, each Psion Teklogix
7535/7530 using the radio link must have a unique number.
6.19.1.1 Host Conn
Conn Type
The options for this a parameter vary depending on the type of application you are
running – ANSI or TESS and the type of radio installed in your hand-held.
For ANSI applications, this parameter allows you to choose one of the following
types of connections:
802.IQv2, 9010t (TCP Direct) or Telnet. Keep in
mind that choosing
Telnet allows the hand-held to communicate directly with
the host.
Settings
Note: The “Settings” sub-menu is not available when 802.IQv2 is selected as
the “Conn Type”. In addition, this sub-menu varies depending on which
option you’ve selected
Telnet or 9010t.
Conn Type Telnet 802.IQv2, 9010t, Telnet
Settings » see text
Range
Host Conn
Host see text
Port 23 0-32767
Terminal Type VT220 see text
Enter Prompt Press ENTER to connect see text
ESC Prompt Press ESC to cancel see text
Auto Login N» Y/N
Func Key Remap N» Y/N
Arrow Key Remap N» Y/N
Range
Telnet Settings
Host see text
Port 9999 0-9999
Range
9010t Settings