User manual

Chapter 5: Configuration
EAN 13
156
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Variations
When using Code 128, you can choose the bar code variation the scanner will
recognize. The options available are Standard, UCC 128 and EAN/UCC 128.
Double-tap on Variations to display a dialog box listing your options.
Tap on a variation to highlight it, and then tap on OK.
If you choose None, a check is not executed.
Standard
Enable Standard if “Code 128” is desired.
UCC 128
UCC 128 is a variation of “Code 128”.
EAN/UCC 128
To successfully scan this type of bar code, “EAN/UCC 128” must be enabled.
“EAN/UCC” bar codes include group separators and start codes.
Field Size/Chars
Refer to the description beginning on page 154 for details.
5.10.2.4 EAN 13
Enabled
Set this parameter to on to enable “EAN 13” or off to disable it.
Include Country
If this parameter is enabled, the country code is included with the decoded bar
code data.
Include Check
If this parameter is enabled, the check digit is included with the decoded bar
code data.