User manual
Chapter 5: Configuration
Power Tab
146
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Late TX Limit
The value entered for this parameter (measured in milliseconds) sets the maximum
allowable deviation time from the start of a response window during which an 7530
can make a transmission. After this threshold, the transmission will not be attempted
and the 7530 will try again at the next opportunity. For example, suppose this
parameter is set to 5. From the beginning of the response window, the 7530 can be
up to 5 milliseconds late sending a transmission. Beyond this threshold, the
transmission is not attempted. The hand-held waits for the next opportunity.
The allowable range for this parameter is from 1 and 10 – the default value is 2.
Test Polling Values
• Tap on the Test Polling Values button to test the polling values indicated in
this dialog box without committing them to memory.
To commit the new polling values to memory:
• Tap on the OK button – the dialog box is closed and the new values
are saved.
To discard the new values, and retain the existing values:
• Tap on the X button at the top of the dialog box.
5.9.4 Power Tab
Figure 5.69 Power Tab