QS200 Handheld Scanner Programming Manual v 2.
PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 All rights reserved. No part of the contents of this documentation or the procedures described therein may be produced or transmitted in any form or by any means without prior written permission of PSC Inc. Owners of PSC Inc.'s products are hereby granted non-exclusive, revocable license to reproduce and transmit this docu mentation for the purchaser's own internal business purposes.
TABLE OF CONTENTS Introduction Flow Chart 1 Interfaces 2 On/Off Symbologies 3 Code 39 7 Codabar/NW7 8 Interleaved 2/5 9 Standard 2/5 11 Matrix 2/5 12 EAN-13/EAN-8 13 UPC-A/UPC-E 14 CHINESE POSTAL 2/5 15 Reading Modes 16 General Parameters 17 Keyboard Parameters 20 Terminal Type 21 Function Key Setting 23 Function Key Table 24 Function Key Labels 25 Languages 27 i
RS232 Parameters 28 CCD Wand Emulation 31 OCIA Types 32 Magnetic Setting 33 Code Mark 34 Truncate Digits 36 ASCII Table 38 Hexadecimal Labels 39 Pinout Assignments 40 Notes: 1. Options marked by { } are only available for some models. 2. Factory default values are indicated by . 3. All references to numbers in this menu are in Decimal, but you MUST input it as Hexadecimal.
INTRODUCTION Bar Code devices provide an accurate, easy, and fast method of data entry and data storage for computerized information systems.
-1- FLOW CHART START OF CONFIGURATION SELECT INTERFACES SELECT SYMBOLOGIES OPERATION PARAMETERS SET FACTORY DEFAULTS ** ABORT CONFIGURATION * END OF CONFIGURATION ** SHOW VERSION * ** Reject new settings & end. Accept new settings & end.
INTERFACES - 2 - KEYBOARD RS232C CCD WAND EMULATION {OCIA} RESERVED 1 RESERVED 2 To choose an Interface, e.g. KEYBOARD: 1. Scan START OF CONFIGURATION 2. Scan KEYBOARD 3.
- 3 - SYMBOLOGIES CODE 39 OFF ON INTERLEAVED 2 OF 5 OFF ON STANDARD 2 OF 5 OFF ON MATRIX 2 OF 5 OFF ON CODABAR OFF ON
SYMBOLOGIES - 4 EAN-8 OFF ON EAN-13/UPC-A OFF ON UPC-E OFF ON ISBN/ISSN OFF ON EAN/UPC ADDON 2/5 OFF ON
- 5 - SYMBOLOGIES CODE 128 OFF ON CODE 93 OFF ON CHINESE 2 OF 5 OFF ON {MSI/PLESSEY} OFF ON {CODE 11} OFF ON
SYMBOLOGIES- 6 {PHARMACEUTICAL CODE} OFF ON {CODE IV} OFF ON {CODE49} OFF ON Itallian PharmaCode “A” OFF ON EAN-8 TO EAN-13 OFF ON In order to enable Italian PhamaCode, PHARMACEUTICAL CODE should also be enabled.
- 7 - CODE 39 TYPE STANDARD FULL ASCII TRANSMIT START/STOP CHAR OFF ON VERIFY CHECKSUN OFF ON TRANSMIT CHECK CHAR OFF ON CODE39 LABEL ID OFF ON
CODABAR/NW7 - 8 TRANSMIT START/STOP OFF ON TYPE OF START/STOP ABCD/ABCD ABCD/TN E abcd/abcd abcd/tn e TRANSMIT CHECK DIGIT OFF ON VERIFY CHECK DIGIT OFF ON
- 9 -INTERLEAVED 2 OF 5 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.
INTERLEAVED 2 OF 5- 10 To choose BAR CODE LENGTH, e.g. 10 - 20, (0A,14 in Hex): 1. Scan START OF CONFIGURATION 2. Scan BAR CODE LENGTH 3. Scan 0 A 1 4 SET 4. Scan END OF CONFIGURATION CUSTOM DEFINE, user may choose 1 to 3 individual lengths, excluding the range between, e.g. user wants lengths of 12, 16 and 20: (0C, 10 and 14 in Hex) Use above example except: No. 2. Scan CUSTOM DEFINE No. 3.
- 11 -STANDARD 2 OF 5 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.
MATRIX 2 OF 5- 12 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.
- 13 - EAN-13/EAN-8 EAN-13 TRUNCATE LEADING DIGIT =? S 0 TRANSMIT CHECK DIGIT YES NO EAN-8 TRUNCATE LEADING DIGIT =? S 0 TRANSMIT CHECK DIGIT YES NO Example: user wants to truncate 1 (the first leading digit): 1. Scan START OF CONFIGURATION 2. Scan TRUNCATE LEADING DIGIT 3. Scan 0 1 SET 4.
UPC-A/UPC-E - 14 UPC-A TRUNCATE LEADING DIGIT =? S 0 TRANSMIT CHECK DIGIT YES NO UPC-E TRUNCATE LEADING DIGIT =? S 0 TRANSMIT CHECK DIGIT YES NO UPC-E TO UPC-A YES NO See example on page 13
- 15 - CHINESE 2 OF 5 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.
READING MODES - 16 - TRIGGER ON/OFF TRIGGER ON/ GOOD READ OFF CONTINUOUS/ TRIGGER OFF CONTINUOUS/ LED ALWAYS ON TESTING TRIGGER ON/ GOOD READ OFF/ DELAY TIME = ? CONTINUOUS/ GOOD READ OFF/ DELAY TIME = ? CONTINUOUS/ NO TRIGGER
- 17 - GENERAL PARAMETERS TERMINATOR NONE CR KB LF CR/LF SPACE RS232 TAB ESC CTRL-C EXEC STX..
GENERAL PARAMETERS - 18 - TERMINATOR DELAY = ? <4> KEYBOARD <0> RS232 BUZZER PITCH = ? <18> BUZZER <5> DURATION = ? TIME(S) OF DATA COMPARISON TWO ONE POWER UP BEEPING YES NO DATA FORMAT PREAMBLE/DATA/ POSTAMBLE/ TERMINATOR PREAMBLE/DATA/ TERMINATOR/ POSTAMBLE
- 19 - GENERAL PARAMETERS CHARACTER DELAY = ? <4> KEYBOARD <0> RS232 INTERFIELD DELAY = ? <20> SENDING NUMBER OF DIGITS OFF ON
KEYBOARD PARAMETERS - 20 - LOWER CASE UPPER CASE NUMBER KEYS ALPHANUM NUMLOCK PAD KEYBOARD SPEED NORMAL PREAMBLE =? POSTAMBLE =? TURBO 10 Bytes each CANCEL Preamble/postamble ! *Please read PREAMBLE or POSTAMBLE label first
- 21 -TERMINAL TYPE PC/AT, PS/2 30-80 PC/XT PS/2 25,30 IBM5541 IBM PS/55 ST IBM 3472,3477 IBM 5530-SC IBM PS/55 MP IBM 5295 " " " " " IBM 5530-ZC " NEC 9801 " NEC 5262/N8VS2 " CT 500/700 "
TERMINAL TYPE- 22 - {Mac II,SE} " {WYSE} " {ACER D7300} " {WANG} " {THINK PAD} IBM "#
- 23 -FUNCTION KEY FUNCTION KEY EMULATION ENABLE DISABLE Scanner can read Function keys and other special keys, please refer to FUNCTION KEY LABLES. When doing this, Code 39 FULL ASCII must be on. To concatenate a Function Key or other special keys with input data, e.g. F1: 1. Scan START OF CONFIGURATION 2. Scan keyboard PREAMBLE 3. Scan 0 1 SET 4.
FUNCTION KEY TABLE -24H 0 1 L 0 BkSp 1 F1 Home 2 F2 PgUp 3 F3 PgDn 4 F4 END 5 F5 6 F6 7 F7 8 F8 9 F9 Ins A F10 Del B F11 Pad C F12 D Etr E ESC F TAB
-25- FUNCTION KEY LABELS F1 F2 F4 F3 F5 F7 F10 Enter F12 ESC BkSp F9 F11 F6 F8 TAB Home PgUp
FUNCTION KEY LABELS -26- PgDn End ! " # $ Ins % Del & Pad
- 27 - LANGUAGES $ BELGIAN $ DANISH $ FRENCH $ GERMANY $ ITALIAN $ PORTUGUESE $ SPANISH $ SWEDISH $ SWISS $ UK $ US $ WYSIWYG
RS232 PARAMETERS - 28 BAUD RATE ! 300 ! 600 ! 1200 ! 2400 ! 4800 ! 19200 ! 9600 ! 38400 DATA BIT % 7 % 8 STOP BIT % 1 % 2
- 29 - RS232 PARAMETERS PARITY & NONE & ODD & & SPACE EVEN & MARK HAND SHAKING NONE ACK/NAK XON/XOFF RTS/CTS SCANNER READY RTS/CTS DATA READY
RS232 PARAMETERS - 30 ACK/NAK Response Time CTS Observation Time 300 msec 500 msec 1 sec 2 sec 3 sec 5sec ∞ PREAMBLE =? POSTAMBLE =? 10 Bytes each CANCLE PREAMBLE/POSTAMBLE ! * Please read PREAMBLE or POSTAMBLE lable first
- 31 -CCD WAND EMULATION ' BAR=HIGH ' BAR=LOW SCAN SPEED SLOWEST (28cm/sec) SLOW (36cm/sec) ' ' NORMAL ' (49cm/sec) HIGH (80cm/sec) HIGHEST (208cm/sec) ' ' BASE ON 0.
OCIA - 32 OCIA MACHINES " CASIO " NIXDORF " NCR-F " SIEMENS " NCR-S " TEC
- 33 - MAGNETIC SETTING TRACK DELIMITER NONE CR LF CR/LF SPACE TRACK SELECTION TRACK 1 TRACK 2 TRACK 3 TRACK 1&2 TRACK 2&3 {TRACK 1,2&3}
CODE MARK- 34 - ( CODE 39 = ? ( ITF 2/5 = ? ( ( STD 2/5 = ? MTX 2/5 = ? ( CODABAR = ? ( EAN-13 = ? ( ( UPC-A = ? EAN-8 = ? ( ( UPC-E = ? {CODE 11 = ?} ( ( CODE 93 = ? CHINESE 2/5 = ? ( CODE 128 = ? ( {MSI = ?}
- 35 - CODE MARK ( ( {CODE IV} {PHARMACEUTICAL} CODE MARK CANCELLATION ! * Read code type first CODE MARK ON OFF
TRUNCATE LEADING DIGIT - 36 - CODE 39 CODABAR MATRIX 2/5 STANDARD 2/5 INTERLEAVED 2/5 CODE 128 CODE 93 PHARMACEUTICAL CODE IV User can choose only 1 symbology at a time to truncate leading or ending digits. At the same time, the TRUNCATE functions of EAN and UPC codes can also be operating.
- 37 - TRUNCATE ENDING DIGIT CODE 39 CODABAR MATRIX 2/5 STANDARD 2/5 INTERLEAVED 2/5 CODE 128 CODE 93 PHARMACEUTICAL CODE IV EAN-13 EAN-8 UPC-E UPC-A )
ASCII TABLE - 38 - START CONFIGURATION ABORT CONFIGURATION END CONFIGURATION ASCII TABLE H 0 0 1 2 3 4 5 6 7 8 9 A B C D E F NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ ' a b c d e f g h i j k l m n o p q r s t u v w x y z { | } L DLE SP DC1 ! DC2 " DC3 # DC4 $ NAK % SYN & ETB ' CAN ( EM ) SUB * ESC + FS , GS RS .
- 39 - HEXADECIMAL LABELS ' 0 1 2 3 4 ( 5 6 7 8 9 C D A B E F SET
PIN ASSIGNMENTS - 40 TTL Signal Output COLOR FUNCTION BROW YELLO GREEN RED BLUE BLACK PURPLE ORANGE START OF SCAN SIGANLDATA LED INDICATOR TRIGGER POWER ENABLE GND GND SHIELD Vcc +5V 9 PIN DSUB/AMP (F) 1 2 3 5 6 7 8 9 5 PIN DIN (M) 2 5 4 3 3 1 CCD Wand Emulation Signal Output COLOR FUNCTION 9 PIN DSUB/AMP (F) BLUE SIGNAL DATA 2 BROW GND 8 PURPLE Vcc +5V 9 6 PIN DIN (M) 6 2 5 4 3 3 1 6 PIN MINI DIN (M) 6 4 1 2 5 5 3 5 PIN DIN (M) 6 PIN DIN (M) 2 2 3 3 1 1 NOTE: The pin number for the 5 and 6 pin co
- 41 - PIN ASSIGNMENTS RS232 SIGNAL OUTPUT COLOR FUNCTION BROW GND YELLO CTS GREEN RTS ORANGE RX BLUE TX PURPLE Vcc +5V 9 PIN DSUB/AMP (F) 25 PIN DSUB (F) 5 7 8 4 7 5 2 2 3 3 9 25,16
PIN ASSIGNMENTS - 42 RS232/Keyboard Signal Output COLOR BROW BLUE PURPLE ORANGE FUNCTION GND TX Vcc +5V RX 9 PIN DSUB/AMP (F) 25 PIN DSUB (F) 5 7 3 3 9 25,16 2 2 NOTE: RS232 CABLE WITH DC POWER SOCKET FOR DC POWER 5V OCIA Signal Output COLOR FUNCTION RED CLOCK RETURN ORANGE CLOCK GREEN DATA RETURN BLUE DATA WHITE VCC BROW GND 8 PIN DIN (M) 9 PIN DB-(F) 4 1 3 2 1 3 2 4 5 7 7 8 10 PIN 3 9 5 7 10 1
Asia Pacific Germany Latin America PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291 PSC GmbH Darmstadt, Germany Telephone: 49 (0) 61 51/93 58-0 Fax: 49 (0) 61 51/93 58 58 PSC S.A., INC. Miami, Florida, USA Telephone: (305) 539-0111 Fax: (305) 539-0206 Australia Italy United Kingdom PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] 0 (2) 9878 8999 Fax: [61] 0 (2) 9878 8688 PSC S.p.A. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.