Specifications
Serial Parameters
Product Reference Guide E-13
Table E-9. Serial Programming Parameters
Code Parameter ID # Type Acceptable Input Predefined Default (C8)
Serial Programming Parameter Enter 1 for On and 0 for Off.
Host select C0 Value
11 = ATs, PS/2s, and
compatibles
15 = IBM terminals
None
Baud rate C1 Value
00 = 300
01 = 600
02 = 1200
03 = 2400
04 = 4800
05 = 9600
06 = 19,200
07 = 38,400
08 = 76,800
05
Data bits C2 Value
07 = 7 bits
08 = 8 bits
08
Parity C3 Value
00 = None
03 = Odd
04 = Even
00
Stop bits C4 Value
01 = 1 bit
02 = 2 bits
01
Enable Xon/Xoff C5 On/Off On or Off Off
Linefeed (LF)
(Valid for CA = 00 only)
C6 Value
00 = None
01 = Strip LF
02 = Add LF
00
Predefined serial defaults C8
End-of-file character C9 Value Any single ASCII character 1A
Protocol CA Value
00 = EOR only
01 = CR with checksum
and ACK/NAK response
02 = Xmodem
01
End-of-record (EOR) character CC Value Any single ASCII character (CR)
Timeout CD Value
00–99
(100-millisecond units)
10
2340.book Page 13 Wednesday, January 29, 2003 12:50 PM