Specifications

3-12 Magellan
TM
8500Xt Scanner
Operational Maintenance
The scanner or scanner/scale will provide dependable service for many
years. The following maintenance procedures will keep your scanner or
scanner/scale operating at peak performance.
Cleaning the Weigh Platter and Scan Windows. Clean the exterior sur-
faces of the horizontal and vertical scan windows at least twice daily with a
nonabrasive, mild, water-based glass cleaner and paper towels or lint-free
cleaning tissues. The textured plastic surfaces and stainless steel can also be
cleaned using the same cleaning agents.
Cleaning the Air Gap/Debris Chutes & Drip Rail. Daily, clear the debris
chutes between the platter and the outer housing. Most items can be
cleared from the debris chutes by carefully running a thin stiff object like a
credit card along all sides of the weighing surface. If necessary, remove the
top cover to clear the debris chutes and drip rail.
Vertical Scan Window Replacement
The Vertical Scan Window enclosed in the All Weighs™ Platter is a
replaceable part. Follow these instructions to remove and replace the win
-
dow:
To remove the Vertical Scan Window:
1. Grasp the platter as shown in Figure 3-3 and gently lift it from the
scanner.