Specifications
2-38 Magellan
TM
8500Xt Scanner
Figure 2-26. Using the Bubble Level
OK OK NO
Bubble Level
6. Reinstall the All Weighs™ Platter and verify that it is flush or just
below flush with the countertop. This is necessary to provide
smooth scanning from either direction. Make adjustments as
needed to align the platter with the counter by moving support
rails up or down, or consider installing screws in positions that
will allow their use in adjusting the unit’s position. Ensure that
leveling is maintained if adjustments are made.
NOTE
Failure to install a scanning-scale in a stable and level position will inhibit
weighing, calibration and zeroing operations. The platter MUST make unob-
structed contact with all
of its supports for proper weighing operation.
7. Once installation is complete, proceed with the Operational Verifi-
cation
procedures that follow.