Specifications

Product Reference Guide 2-37
3. Depending upon the model type, the method used to lift the unit
will vary. For the first model type, hook the fingers of both hands
into the lift handles located along the insides of the scanner walls,
just above the debris chutes as shown in a. Other models contain
lift handles that must be rotated up into position for use as shown
in b. DO NOT attempt to lift the unit using the plastic edges,
scale frame, or any features other than the lift handles.
Figure 2-25. Using the Lift Handles
Lift Handles
ab
...or rotate Lift Handles up
or...
4. Lower the unit into the counter opening, ensuring that none of
the cables are pinched, pierced or crimped.
5. View the bubble level (if present
1
) located on the scanner's spider
assembly to ensure the scanner is level. As shown in the insert of
Figure 2-26, the air bubble should appear fully within the circle
indicated. The air bubble can touch the circle, but must not over-
lap it. Apply shims beneath the scanner bottom or adjust the shelf
to allo
w level installation.
1. The bubble level is present only on certain models.