Specifications

F-12 Magellan
TM
8500Xt Scanner
Code 39
Check character must be included in label data.
Label length including start, stop and check characters and
excluding prefix characters must meet requirements imposed by
the main scanner's fixed or variable label length control for this
symbology type.
Start and stop characters "*" must be included in label.
Prefix must be ASCII characters ']A0' or ']A1'.
Example: '*]A0Code 39.TEST*'.
Codabar
Check character must be included in label data.
Label length including check character and excluding prefix char-
acters must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.
Prefix must be ASCII characters ']F0'.
Start stop character sets must meet the matching requirement set
forth by the scanner configuration item
Codabar Start Stop Char-
acter Match.
Start stop character sets s must be of the form ABCD/ABCD
and must be included in the label.
Example: ']F0s$99.95s' (the lower case s’ at each end of the
example is a placeholder for the start stop character set).
MSI/Plessey
Check character must be included in label data.
Label length including check character and excluding prefix char-
acters must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.
Prefix must be ASCII characters ']M0'.
Example: ']M0144769254'.