Specifications

7-202 Magellan
TM
8500Xt Scanner
DataBar Expanded Length 2
If DataBar Expanded Length Control is set to Fixed-Length decoding, this
feature specifies DataBar Expanded second fixed length. If DataBar
Expanded Length Control is set to Variable-Length decoding, this feature
specifies the maximum label length.
NOTE
When in Fixed Length mode, if Length 2 is set
to the value of 00 (zero),
then only Length 1 will apply.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET DATABAR EXPANDED LENGTH 2
below. You’ll need to cover any unused barcodes on this and the
f
acing page to ensure that the scanner reads only the barcode you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that
represent the desired label length. The selectable range for this
option is 00 to 74.
Pad all single digit numbers with a leading
zero to yield a two-digit entry (00-74).
4. Complete the programming seque
nce by scanning the SWITCH
barcode.
SET DATABAR EXPANDED LENGTH 2