Specifications

7-52 Magellan
TM
8500Xt Scanner
EAS Deactivation Duration — Retry
Specifies the amount of time EAS deactivation is operative once the func-
tion has been initiated following EAS tag detection (prior to barcode
re
ad).
NOTE
This setting pertains only to units configured for EAS Coupled Mode. Refer-
ence the “EAS Mode ” description for more information about Coupled and
Decoupled EAS operation. Also reference “EAS Retry Count .”
.
To set the EAS Deactivation Duration — Retry:
1. Scan the SWITCH barcode.
2. Scan the barcode,
SET EAS DEACTIVATION DURATION — RETRY
below. You’ll need to cover any unused barcodes on this and the fac-
ing page to ensure that the scanner reads only the barcode you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired duration. The selectable range is 1-255, which is
the duration
in 10-millisecond increments. Pad all single and double
digit numbers with leading zeroes to yield a 3-digit entry (001-255).
Examples:
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
The scanner will automatically exit P
rogramming Mode when the appro-
priate amount of digits have been scanned
SET EAS DEACTIVATION DURATION — RETRY