Specifications
7-46 Magellan
TM
8500Xt Scanner
EAS Beep Duration
Sets the duration of the EAS successful deactivation beep, specified in
10ms increments. The beep only occurs if EAS mode is not disabled.
To set the EAS Beep Duration:
1. Scan the SWITCH barcode.
2. Scan the barcode,
SET EAS BEEP DURATION below. You’ll need to
cover any unused barcodes on this and the facing page to ensure that
the scanner
reads only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired EAS Beep Duration. The selectable range is 0-
255, whic
h is the timeout in 10-millisecond increments. Pad all sin-
gle and double digit numbers with leading zeroes to yield a three-
digit ent
ry (000-255).
Examples:
000 = EAS beep disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. Complete the programming sequence b
y scanning the SWITCH
barcode.
SET EAS BEEP DURATION