Service manual

METTLER TOLEDO
DIVA Service Manual 3
1.4 Power Requirements
Two different power options exist:
1. If the scanner is equipped for use with MT weighing modules, power will be supplied via a white
FFC cable located in the front of the scanner. The DIVA-P2 is equipped with an appropropriate
FFC socket for this cable. With this option, the scale is powered by the scanner’s power supply.
2. The DIVA-P2 communication cable has an additional (moulded) socket that can be connected with
the wall mount power supply that is supplied with the DIVA-P2. With this options, the scale and
scanner are independently powered, and both have their own power supply.
3. The DIVA-P2 communication cable has an additional (moulded) socket that can be connected with
the barrel plug of the Y-harness that is included in the box. The remaining plug of that Y-harness
has to be connected to the scanner’s power socket, the Y-harness’ socket has to be connected to
the scanner’s power supply.
With both options the scale is powered by the scanner’s power supply. Please refer to the DIVA-P2
installation guide for more details on powering up the system.
1.5 Temperature and Humidity
Working temperature range: -10 to +40
o
C (+14 to +114F) at 10 to 85% humidity, non-condensing.
Storage temperature range: from -25 to +50
o
C at 10 to 85% humidity, non-condensing.
1.6 Weights and Measures Approval
EC Type-approval: T6941
EC Test Certicate: TC6942 (when the scale is used without the Mettler-Toledo displays
NTEP: Certificate of Conformance Number 06-024
Canadian Approval: AM #5591
1.7 Option
Remote display bracket
Dual Display