Service manual

METTLER TOLEDO
DIVA Service Manual 66
6.1.14.2 Command Descriptions
ECR Time out Scale COMMENTS
STX (02h)
500ms
ACK (06h)
@ (40h)
1 (31h)
P4 (30h to 39h)
P3 “
P2 “
P1 “
P0 “
CR (ODh)
LF (0Ah)
The cash register sends the unit price (P1-4) to the scale. When
received, the scales send back the weight, the unit price and the
price to pay. All information are memorized in the cash register (PLU,
Totals etc..).
STX (02h)
The dialogue begins with STX and ACK if no answer occurs, STX can
be sent 8 times with a delay of 500ms.
500ms
ACK (06h)
1 (31h)
0 (30h)
CR (0Dh)
LF (0Ah)
100ms/300ms
STX (02h)
ACK (06h)
W4 (30h to 39h)
W3 “ “
W2 “ “
W2 “ “
W1 “ “
W0 “ “
UP4 (30h to 39h)
UP3 “ “
UP2 “ “
UP1 “ “
UP0 “ “
PtP5 (30h to 39h)
PtP4 “ “
PtP3 “ “
PtP2 “ “
PtP1 “ “
PtP0 “ “
0 (30h)
CR (0Dh)
LF (0Ah)
Note: When the cash register requests the weight information, unit
price, price to pay, the scale sends back the data when the weight is
stabilized. So, it can last up to 1 or 2s.
P = Unit Price
W= Weight
UP= Unit Price
PtP=Price to Pay
If information is not available (too much weight, nul unit price, etc…)
the scale sends the error code “3Ch” in W4