Service manual

METTLER TOLEDO
DIVA Service Manual 13
Group 2
Press Zero to Enter
Press Tare to go to Group 3
Group.Step Function Possible Selections Master Mode Access
2.1 Tare Enable
ON – Enables tare function.
OFF – Disables tare function.
Yes
2.2 Chain Tare Enable
ON – Enables multiple tares.
OFF – Only one tare per transaction is allowed.
Yes
2.3*
Total Price Round
(To Nearest 0 or 5)
ON – The total price will round up or down to 0 or 5.
OFF – Total price will not be rounded.
No
2.4 Digital Filter Selection 0 - 3 – Minimal to High No
2.5 GEO 0 through 31 – See GeoCal chart below No
2.6 Calibration
No – Do not enter calibration mode
Yes – Calibrate scale
No
2.7 Display (1 or 4 Line)
0 – None
1 – 1 Line
2 – 4 Line
Yes
2.8 Display Update Rate 0-100 – Adjust display rate Yes
2.9 Enter Flash Mode
ON – Enter Flash Mode
OFF – Do not enter Flash Mode
No
Group 3
Press Zero to Ente
r
Press Tare to go to Group 4
3.1 Baud rate
0 – 1200
1 – 2400
2 – 4800
3 – 9600
Yes
3.2 Parity
0 – None
1 – Even
2 – Odd
Yes
3.3 Data
0 – 7 data bit
1 – 8 data bit
Yes
3.4 Bit stop
0 – None
1 – 1 stop bit
2 – 2 stop bit
Yes
3.5 Chose Protocol
0 = Disabled
1 = NCI-ECR (WO)
2 = (reserved)
3 = 8217 Mettler-Toledo (WO)
4 = 8213 Mettler-Toledo (WO)
5 = EPOS 1 (WO)
6 = EPOS 2 (WO)
7 = (reserved)
8 = Dialog 06 (PC)
9 = Dialog 04/02 (PC)
10 = Extended Dialog 06 (PC)
11 = ICL (WO)
12 = Shekel (WO)
13 = RIVA 5462 (WO)
14 = IP3 (PC)
15 = (reserved)
Yes
Group 4
Press Zero to Ente
r
Press Tare to go to EXIT
4.1 Weight Change
00 - No Weight Change Required
yy - 01 to 99 weight change divisions required
No
4.2 Return to Zero
0 - No Return to Zero Required
1 - Return to Zero Active
No