3.3 Set up Soft Switch and Default Table
Group.Step Function Possible Selections Master Mode Access
Group 1
Press Zero to Enter
Press Tare to go to Group 2
1.1 Country Select
DE (Germany)
FR (France)
US (USA)
CA (Canada)
AT (Austria and Croatia and Slovenia)
ES (Portugal and Spain)
BE (Belgium, Netherland, Poland and England)
IT (Italy)
CH (Kazachstan and Switzerland)
UA (Ukraine)
RU (Russia)
HU (Hungary)
SK (Slovakia)
CZ (Czechia)
EXPORT (General export)
CN (China)
No
1.2 Initialize to Defaults
YES – Soft switches will be reset to factory defaults
NO – Soft switches will remain in current configuration
No
1.3 Beeper
0
Beeper will not sound at any time
1 – Scale will not “beep” when a key is pressed
2 – Scale will not sound when a key is pressed, but it will
“beep” when sending command of NCI-ECR
3 – Scale will sound when a key is pressed, and it will “beep”
when sending command of NCI-ECR
Yes
1.4 Zero cursor
ON – Display zero cursor.
OFF – Disable zero cursor.
Yes
1.5 Decimal point
ON - .
OFF - ,
Yes
1.6* Decimal Position 0 - 4 – Digits right of the decimal for Unit and Total Price fields. No
1.7 Auto-clear of Tare
ON – Tare is automatically cleared when weight is removed.
OFF – Tare is not cleared when weight is removed.
No
1.8 Weight unit
1 – lbs range (0 to 30 lbs)
2 – kg range (0 to 15kg)
3 – kg multi-interval (0 to 6kg, 6 to 15kg)
4 – lbs multi-interval (0 to 15lb, 15 to 30 lb)
No
1.9 Expanded Weight Display
ON – Division quantity is displayed, Maximum is 30000.
OFF – Weight is displayed in normal display increments.
No
1.10 Blank Weight Enable
ON – Display weight till weight is stable
OFF – Display weight all the time
No
1.11 Main Calibration Button
ON – Calibration button on the Main PCB is Enabled
OFF – Calibration button on the Main PCB is Disabled
No
1.12 Currency 0 - 9 – This selection is used for VD No