Service manual

METTLER TOLEDO
DIVA Service Manual 7
For Weigh Only Version:
The Weigh Only version comes with a tower mount.
Assemble the Weight Only tower as is illustrated here:
Please refer to the Installation Guide for instructions on mounting the DIVA-P2 to the scanner.
1. Level the scale by turning the adjustable feet on the bottom of the unit. Adjust the feet until the level
bubble is in the center of the circle.
Bubble indicator:
Correct Wrong
2. Put the platter on top of the DIVA scale.
3. Connect the tower display cable to the appropriate port on the scanner.
4. Connect the power cord from the wall transformer to the scanner as described in section 1.4.
2.4 Power up sequence
Note: Before powering on the DIVA scale, always make sure there is nothing on the platter.
Apply power to the scanner. The scale will go through a series of self-tests and then will proceed to
normal operating mode. The power-up sequence is as follows:
1. All segments of the display characters are lit*. This verifies operation of all segments.
2. The scale displays the country code and GEO code, software part number and revision.
3. The scale then captures zero and is ready for normal operation.
*If the display does not light up correctly the scale could be set up for a different (WO or PC) display.
To change the scale to the correct display type hold down the tare button on the display while
recycling power.
Display
Display Cable
Display Bracket
Display Tower