Specifications
179
6 401032 000015
SCALE ENFORCED ZERO RETURN - ENABLE
Scan this label to enable the Enforce Zero Return
feature. This feature monitors the scale to ensure
that it returns to zero within four minutes after the
last weighing transaction was completed. If the
scale fails to return to zero within the allotted time,
the scale will be rendered inoperable until
rezeroed.
If the display shows a negative weight prior to a
transaction, weighing operations will not be
allowed until the scale is rezeroed.
NOTE
In some cases local regulatory agencies
will require the scale to be recalibrated.
Check to ensure your actions are in compli-
ance with these requirements.