Specifications

Series 9000E Scanner/Decoder
5-32
If NO is selected the output of scanner will be one of the following:
bar code GC text GR pulse GC pulse
bar code NC text GR pulse NC pulse
NR No NC text NR pulse no NC pulse
If formatting is modified the Good Read Text will appear before or after
the bar code.
Operator Action:
1. With the cursor positioned at the end of the GOOD READ line type
in the desired duration in milliseconds. Press ENTER to select this
value and move to the next line.
2. With the cursor positioned at the end of the NO READ line type in
the desired duration in milliseconds. Press ENTER to select this
value and move to the next line.
3. With the cursor positioned at the end of the GOOD COMPARE line
type in the desired duration in milliseconds. Press ENTER to select
this value and move to the next line.
4. With the cursor positioned at the end of the NO COMPARE line
type in the desired duration in milliseconds. Press ENTER to select
this value and move to the next line.
5. With the cursor positioned at the end of the OUTPUTS ARE
ACTIVE line use SPACE to display the choices; High or Low.
When the desired condition is displayed, press ENTER to select
this condition and move to the next line.
6. With the cursor positioned at the end of the GATE INPUT IS
ACTIVE line use SPACE to display the choices; High or Low.
When the desired condition is displayed, press ENTER to select
this condition and move to the next line.
7. With the cursor positioned at the end of the GOOD READ BASED
ON line use SPACE to display the choices; All Fields, First Field, or
Any Field. Press ENTER to select.