Specifications

LOCAL FORMATTING
5-31
GOOD COMPARE - The duration of the output pulse that occurs on a
Good Compare condition can be programmed. Values up to 9999
milliseconds may be entered.
NO COMPARE - The duration of the output pulse that occurs on a No
Compare condition can be programmed. Values up to 9999
milliseconds may be entered.
OUTPUTS ARE ACTIVE - Outputs can be made active high or active
low. An active high output would normally be low (logic 0) and go high
(logic 1) when activated. An active low output is the opposite.
GATE INPUT IS ACTIVE - Gate input can be made active high or active
low. An active high gate input would normally be low (logic 0) and go
high (logic 1) when activated. An active low gate input is the opposite.
GOOD READ BASED ON - When multiple fields are used this entry line
defines the criteria for Good Read Pulse Output.
All Fields - Every code type for each field must be identified for
a Good Read Pulse. This is the default condition.
First Field - Good Read pulse asserted if first field contains data.
Any Field - Good Read pulse asserted if any field contains data.
TRANSMIT NOCOMPARE ON NOREAD - This option will allow the
user greater control over the No Compare output pulse.
If YES is selected the output of scanner will be one of the following:
bar code GC text GR pulse GC pulse
bar code NC text GR pulse NC pulse
NR NC text NR pulse NC pulse