Specifications

Series 9000E Scanner/Decoder
5-20
Field Descriptions:
COM HARDWARE PROTOCOL - Allows choice of one of three
hardware protocols: RS-232, RS-422, RS-485 2 wire*, RS-485 4 wire*.
* intended to be used with LazerData Multidrop only
COM BAUD RATE - The baud rate can be set using any of the following
values: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400.
COM PARITY - Parity for this port can be set to none, even or odd. If
set to none there is no parity bit in the transmission.
COM DATA BITS - The number of data bits per character can be 7 or 8.
COM STOP BITS - The number of stop bits per character can be 1 or 2.
RTS/CTS FLOW CONTROL - This controls whether the RTS and CTS
handshake signals will be used for RS-232 or RS-422.
COM SOFTWARE PROTOCOL - Software protocols may be specified if
desired. If NONE is chosen, no software protocol will be used. Other
choices are: ACK/NAK (ACK/NAK Timeout is explained on page 5-9),
XON/XOFF (short cut keys are CTRL Q and CTRL S, respectively),
INTERMEC and LazerData MULTI-DROP.
COM ECHO/PASS THROUGH - Each transmission received on this port
can be echoed (repeated) to another port. The choices are NO ECHO,
HOST, LOCAL, or BOTH. Selecting NO ECHO will not echo any
transmission. Selecting HOST will re-transmit the input signal on this
port to the output on this port. Selecting LOCAL will echo the input
signal on this port to the output on the local port. Selecting BOTH will
echo the input signal on this port to the output on both ports.
TRANSMIT ON ANY NOREAD - User can determine whether a data
transmission will (YES) or will not (NO) be made when a No Read
condition occurs in ANY field.