User`s guide

R44-1430 11
V
ERIFYING SCANNER OPERATION
Prior to installation, we recommend that you connect the scanner and
power supply to AC power to ensure that the scanner is fully
functional.
1. Plug the DC power connector from the AC/DC power
supply into the scanner.
2. Connect the IEC end of the AC power cord into the
AC/DC power supply.
3. Plug the AC power cord into an AC power outlet.
The scanner should emit a tone
indicating that it has passed the Power-
Up Self-Test routine, and the green
lamp will light continuously indicating
that the scanner is ready for operation.
Since the scanner is not connected to a
host terminal, it may only read one or
two labels before it must be reset.
This is normal because some terminal
interfaces require the scanner to store
label data until the POS terminal
signals that it is ready to receive the
data.
If the scanner powers-up, but the
green lamp begins flashing and the
speaker repeats a series of tones, go to
the section titled, Problem Isolation.