User's Guide 39
Electrical Specifications
The Duet scanner can draw power from an approved external
AC/DC power supply, or can receive power from the host
terminal.
WARNING
Use only AC/DC Power Supplies approved for the
Duet
scanner
and ordered from PSC. Use of other power supplies may cause
damage to the product which is not covered by the factory
warranty.
Scanner Input Power Specifications
Input voltage 4.7 to 14 volts DC
Power Consumption 3.0 Watts maximum
Input Voltage Ripple 500 mV DC maximum
External AC to DC power Supply
Output: 12 VDC @ 600 mA