Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ Product Reference Guide
PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC").
Table of Contents Chapter 1. Introduction .................................................................................... 1-1 Manual Overview ........................................................................................... 1-1 How to Use This Manual ............................................................................ 1-2 Scanner Nomenclature ................................................................................... 1-3 Connectors .............................................
Chapter 5. Programming .................................................................................. 5-1 Introduction to Label Programming .................................................................. 5-1 Understanding the Basics ............................................................................... 5-1 Integrating the Scanner With Your Host System ................................................ 5-1 Customizing Your Scanner’s Operation ....................................................
RS-232 Host Echo .................................................................................. 5-71 RS-232 Host Echo Quiet Interval .............................................................. 5-72 RS-232 Ignore Host Commands ............................................................... 5-73 RS-232 TTL ........................................................................................... 5-74 RS-232 TTL Invert .................................................................................
UPC-A 5-Digit Supplemental Label ID ...................................................... 5-127 UPC-A 128 Supplemental Label ID .......................................................... 5-128 UPC-E Enable ............................................................................................ 5-129 UPC-E Number System Character Transmission ........................................ 5-130 UPC-E Check Character Transmission ......................................................
RSS Expanded EAN-128 Emulation ......................................................... 5-181 RSS Expanded 2D Component Enable ..................................................... 5-182 RSS Expanded AIM ID .......................................................................... 5-183 RSS Expanded Label ID ........................................................................ 5-184 RSS Expanded Length Control ...............................................................
I 2 of 5 Minimum Label Length ............................................................... 5-228 I 2 of 5 Fixed Length 1 .......................................................................... 5-229 I 2 of 5 Fixed Length 2 .......................................................................... 5-230 I 2 of 5 Stitching .................................................................................. 5-231 Codabar Enable ...............................................................................
Standard 2 of 5 Fixed Length 1 .............................................................. 5-276 Standard 2 of 5 Fixed Length 2 .............................................................. 5-277 Standard 2 of 5 Stitching ...................................................................... 5-278 Appendix A. LED/Beeper Indications & Controls ................................. A-1 Volume/Tone Push Button .........................................................................A-2 Green LED Indicator ...
viii Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Chapter 1 Introduction This Product Reference Guide contains comprehensive instructions on how to install the scanner, how to program it using special programming feature bar code labels, and advanced user information as described in the following overview. Manual Overview Chapter 1, Introduction, presents the manual’s contents, describes features and specifications, provides regulatory and safety information, and lists the bar code symbologies the scanner will read.
Introduction Appendix B, Cable Information, outlines wire requirements, connector specifications and pinout details for associated product cabling. Appendix C, Keypad, furnishes bar codes representing the digits and characters required to enter extended programming data needed during certain programming sessions. Appendix D, Host Commands, contains a partial listing of available host commands that can be used with a compatible host interface.
Scanner Nomenclature Manual Conventions ‘NOTE’ blocks contain information that is helpful and recommended. They provide information that is critical to operations and/or procedures described in this manual. ‘CAUTION’ blocks inform you that proper handling (adherence to the procedures described) is required to avoid damage to equipment and/or property. ‘WARNING’ blocks alert you to potential physical harm or injury.
Introduction Connectors The appearance of the connector panel will vary depending upon the factory options purchased with your model. Reference Figure 1-2. Figure 1-2. Connector Panel Scanner Host Aux. Port Power EAS Opening Scanner Host EAS Connection · Electronic Article Surveillance Connection Connection to this port is Optional 1-4 POS TERMINAL Aux.
Physical Parameters Physical Parameters This section provides specifications for performance, environmental and electrical parameters. Reference the second section of this manual, Site Preparation and Installation, for physical measurements of all models and some accessories. Scanning The scanner has a scan zone immediately in front of (or above) the scan window where the scanner projects laser light in order to scan items. Scan lines form a zone where bar code labels are read.
Introduction Figure 1-4. Environmental Specifications Operation +40 C 10 C +104 F 50 F Temperature 10 to +40 C 50 to +104 F Illumination Artificial Light: 450 Foot-candles Dust Resistant Optics Cavity, IP5X Sunlight: 0-8,000 Foot-candles Humidity 5 - 95% NC Storage +70 C +158 F -40 C POS -40 F Scan ner Temperature -40 to +70 C -40 to +158 F Electrical Specifications Before installation, always verify that the site’s electrical service meets the scanner’s requirements.
Electrical Specifications Power Supply The scanner utilizes the following power supply models. VOLTAGE PART NUMBER 120V US 4004-0705 230V UK 4004-0706 240V SAA 4004-0707 100V MITI 4004-0708 230V EURO 4004-0709 120V Desktop US 4004-0710 Safe operation of your scanner or scanner requires properly grounded electrical outlets. Be sure to have a qualified electrician certify the earth-ground connection on circuits which will be used to power the unit.
Introduction Laser and Product Safety Laser safety requirements are based on IEC Standard Publication 60825-1 (2001) and CDRH 21CFR, Chapter 1, Subchapter J and (CDRH) Laser Product Performance Standard, User information [1040.10(h)1]: • User Maintenance. No user maintenance of the system other than cleaning of the scan window(s) is required. • Radiant Energy. The scanner is an IEC Class 1 and CDRH IIa laser product. The system uses two embedded Class 3R Visible Laser Diodes (VLDs) operating at 650.
Laser and Product Safety Safety precautions to be taken: No adjustments or alteration of the scanner housing are to be attempted by the user. CAUTION WARNING The failure of the facet wheel motor while the unit is continuing to emit a laser beam causes the emission levels to exceed those for inherently safe operation. The unit has safeguards to prevent this occurrence.
Introduction Labeling Regulatory, reference and safety labeling for both models is shown in Figure 1-5 and Figure 1-6. Figure 1-5. Labeling: Model 2200VS PSC Inc. 959 Terry Street Eugene, OR 97402 USA XXXXXXXXXXXX Product of USA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Labeling Figure 1-6. Labeling: Model 2300HS IEC CLASS 1 LASER PRODUCT Class IIa Laser Product. Avoid long term viewing of direct laser light. Appareil á laser de classe IIa. Eviter toute exposition prolongée de la vue à lumière laser directe. 6-1018 Host Aux EAS Opening Scanner Host PSC Inc. 959 Terry Street Eugene, OR 97402 USA XXXXXXXXXXXX Product of USA This device complies with Part 15 of the FCC Rules.
Introduction Agency Compliances The scanner meets or exceeds the requirements for its device type as set forth by the following agencies and regulations: COUNTRY COMPLIANCE COMMENTS Electrical United States UL 1950 TÜV NRTL Canada CAN/CSA C22.2 No.
Bar Codes Supported Bar Codes Supported The scanner can read/decode the following bar code types (symbologies): • UPC Versions A & E • UPC Supplementals and Add-ons (2 & 5 digit supplementals and Code 128) • Reduced Space Symbology (RSS) RSS-14 and RSS expanded; both support stacked component.
Introduction NOTES 1-14 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Unpacking Chapter 2 Site Preparation and Installation This chapter outlines the procedures for unpacking the scanner, verifying function, preparing the countertop or wall, routing cables, and installing the scanner. Unpacking To unpack the unit: • Inspect the package for signs of damage that may have occurred during shipping. If damage is found, report it to your carrier immediately. • Lift any accessories from the box, including the AC/DC Power Supply, and the Quick Reference Guide.
Site Preparation and Installation Operational Verification Follow these steps to ensure that your unit has arrived undamaged and is fully functional before installing it in the counter and connecting it to your POS system: 1. [2200VS scanners ONLY] Remove the mounting bracket. 2. Plug the connector from the AC/DC Adapter into the scanner (see Figure 2-1). Figure 2-1. Scanner Connections Scanner Host Aux.
Installation: Model 2200VS 4. The scanner should beep to indicate it has passed the power-up Selftest routine, and the green LED (lamp) will light continuously, indicating the scanner is ready to scan. Reference Chapter 4, Problem Isolation if the scanner does not perform as expected. NOTE 5. Scan a few known-good bar code labels to verify operation. Upon reading each bar code, the scanner should beep once and flash its green LED.
Site Preparation and Installation 2. Determine if a cable-routing hole is necessary. If so, hold the scanner or mounting bracket in the desired, installed position to determine the center of the hole. Mark the center and drill a 1-1/4” (3.2cm) hole. 3. Secure the mount to the counter or wall using two #6 (3.5mm) pan head screws (see Figure 2-2d).
Installation: Model 2200VS Figure 2-2.
Site Preparation and Installation Installation: Model 2300HS The Magellan® 2300HS scanner is mounted flush with the countertop to promote comfortable and ergonomic slide-through scanning. Installation as described below. 1. Determine the best location for scanner. Some considerations are: • Proximity to the user. Verify that checkstand features allow the unit to be within easy reach of the user, without interfering with cash drawers or other equipment.
Installation: Model 2300HS Figure 2-3. Countertop Modification Options a. Shelf installation b. Adapter w/flange above counter 6.07" (154.2mm) Cut hole 6.26" (159mm) Rim of adapter 6.07" (154.2mm) 6.26" (159mm) Cut hole Rim rests on top of counter 3.42" (86.9mm) 3.47" (88.1mm) Shelf Depth c. Adapter w/flange recessed to be flush with counter 7.40" (188mm) Radius 0.21" (5.3mm) x4 Routing is 0.050" (1.27mm) deep 7.91" (201mm) 6.26" (159mm) Routed ledge for rim Cut hole 6.
Site Preparation and Installation Figure 2-4. Magellan® 2300HS Cable Routing Options Connector Cover 9. Verify operation by scanning a few known-good bar code labels. The scanner should now be communicating the bar code data to the POS terminal. Reference Chapter 4, Problem Isolation if the scanner does not perform as expected. NOTE This completes the installation instructions for this model.
Chapter 3 Operation and Maintenance The information contained in this section describes how to operate and maintain the scanner. Topics include scanning tips, and scan window cleaning and replacement.
Operation and Maintenance Scanning Items: Model 2200VS Item bar codes are scanned by either... • sliding or pushing items through the scan volume in a right-to-left or left-to-right motion (see Figure 1a). This is known as “Sweep” scanning, and is the best choice for high throughput super- and hypermarket installations where it is necessary to minimize the need to grip or lift items. • moving the bar code directly toward the scan window to be read (see Figure 1b).
Scanning Items: Model 2300HS Scanning Items: Model 2300HS The scanner is mounted so its scan window is flush with the countertop. This allows for maximum working space, and also permits the user to slide items over its surface without having to grasp or pick them up. Bar codes are effortlessly scanned when swept through the zone projected from the substantial scan window as shown in Figure 1a. NOTE Facing bar code labels in the direction of scanning, or toward the scan window will optimize the scan rate.
Operation and Maintenance Operational Controls The function of scanner controls and indicators is listed in Appendix A, LED/Beeper Indications & Controls. Turn to that appendix for full details. Operational Modes The scanner features a number of modes that are important to both the user and the system support personnel. These modes can be combined into three groups: pre-operational, operational; and additional functions.
Operational Modes Error Reporting If a fatal error is detected during Selftest or operation, the scanner will not advance to Normal Operation Mode. Selftest diagnostics will cause the scanner to sound a long, low tone. When this occurs, error codes may be accessed by momentarily pressing the Volume/Tone Push Button. The beeper and LED will then emit a coded series of indications to assist the repair technician in identifying the failed component.
Operation and Maintenance Once the scanner enters Normal Operation, it begins a countdown sequence. If there is no activity during a preset period of time (also called time-out1), the unit will shut off the laser and/or motor in order to prolong the life of the electrical and mechanical components. Once the scanner has timed out, it enters Sleep Mode. Sleep Mode After the scanner has been left idle for a preset period of time, the laser and/or motor automatically turns off (goes to sleep).
Additional Functions Additional Functions Additional scanner functions include programming, running scanner diagnostics, or initiating a reset. Programming Scanners are typically programmed at the factory to settings specified by the customer. Generally, POS system interface and bar code symbologies are pre-configured to operate in the target environment. Chapter 5 contains the necessary instructions, bar codes, and descriptions to program/ reprogram scanner settings.
Operation and Maintenance Scanner Reset As with any electronic equipment, it is sometimes necessary to reset the electronics. The reset procedure allows you to initiate a reset command to the scanner. This may be necessary if the POS terminal has been switched off or the store system has been reset while the unit is on. Reset can also be used to initiate and run the scanner’s internal Selftest routine.
Chapter 4 Problem Isolation In the event of a suspected functional problem, use the troubleshooting references provided in this section. This useful information will help you identify and resolve the cause of the problem. The scanner incorporates features that indicate when a problem occurs. The scanner may: • emit a series of tones • flash the LED (lamp) Three error reporting modes are used: Power-Up Selftest, Operational tests and Diagnostic tests.
Problem Isolation Diagnostic Tests See Chapter 3, Scanner Diagnostic Mode for details about running diagnostic tests for the scanner. If a problem is discovered during diagnostics, the scanner will provide feedback about the source of the problem. The remainder of this section describes these failure indications and includes troubleshooting flowcharts to help isolate the problem. Diagnostic Procedures Your Point-Of-Sale (POS) system may contain many components that operate as a system.
Error Codes Error Codes If an error is detected, the scanner will sound a long low tone (for three seconds) and flash its LED, indicating a failure. When this occurs, press the Volume/Tone Push button to hear the error code. If it is configured to do so, the scanner will sound a series of beeps corresponding to the error code and/or flash its LED simultaneous to the beeps. The table below describes what these codes mean and what action should be taken for each.
Problem Isolation Flowcharts The problem isolation flowcharts on the following pages allow you to identify and troubleshoot problems with your system. Figure 4-1. Problem Isolation: Start For units using an AC/DC adapter, verify that... 1. AC Adapter is connected to a functional AC outlet. 2. Power cord is firmly connected to scanner. If your unit is a model which receives Power Off the Terminal POT), verify that the I/F cable is securely connected at both ends.
Flowcharts Figure 4-2. Problem Isolation: Selftest SELFTEST START Is the LED blinking in error ? Scan the Factory NO Is the error code 1 ? YES Defaults bar code in Section 6 to enable the default configuration file. Restart the unit. No interface selected (Null Interface). Select an interface.
Problem Isolation Figure 4-3. Problem Isolation: Poor/No Reading Have you verified that the scan window(s) is/are clean and scratch-free? POOR/NO READING START Enter Scanner Diagnostic Mode by holding the Volume/Tone Push Button for 4 seconds (until first 3, and then 6 rapid tones are sounded) then release. Scan a known-good bar code. A good read is signified by one flash of the LED and a single beep1.
Flowcharts Figure 4-4. Problem Isolation: No Transmit to POS NO TRANSMIT TO POS START Check the interface (I/F) cable connections. If possible, retest the system using a knowngood I/F cable. Does the scanner pass the data to the POS ? YES NO Verify programmable parameters using the information and programming bar codes provided in Section 5. Check interface and I/F options, inactive symbologies and other configurable features.
Problem Isolation NOTES 4-8 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Chapter 5 Programming Introduction to Label Programming The programming bar code labels contained in this manual will allow you to customize and configure features and settings for your scanner. To ensure full compatibility and proper function, use only the programming bar codes in this manual and other product-specific publications to program scanner features.
Programming You may also want to contact the dealer or your system administrator if you have no record of how your scanner was pre-programmed at the factory. Scanners are typically programmed with the default settings for specific interface types (see Appendix E, Factory Defaults for more information); however, your scanner may have been custom configured with settings that are unique to your company or application.
Programming Overview • Symbology Programming - gives the scanner the capability to autodiscriminate as few as one, and as many as all available symbologies. For optimal scanner performance enable only those symbologies required. Additionally the scanner may be programmed with the standard options available for the various symbologies, such as check digit, minimum label length, fixed and variable length bar codes, etc.
Programming Programming via Handheld Device The scanner can also accept programming via its auxiliary port using a handheld scanning device. Eligible handheld devices must have the ability to transmit Code 128 function codes such as the programming bar codes presented in this manual. PSC models QuickScan® 1000 and QuickScan® 6000 support this functionality. Handheld data format requirements (baud rate, parity, etc.) are presented in Appendix F of this manual.
Programming Overview Programming Session A typical programming session is conducted as follows: 1. Scan the SWITCH bar code to place the scanner in Programming Mode. Depending upon its current programming, the scanner may emit a beep or beeps, indicating it has read the bar code and the green LED will flash on and off slowly while the scanner remains in Programming Mode. Normal scanning functions are disabled. 2. Scan the programming bar code(s) that is (are) specially encoded to make the desired changes.
Programming NOTE It is recommended that programming sessions be limited to one feature at a time. Should you make a mistake in the programming sequence, it can be difficult to discover where an error has been made if several features are programmed at once. Additionally, it can be confusing to determine which features may or may not have been successfully set following such a session. 3. Scan the SWITCH bar code to save any new settings and exit Programming Mode.
Programming Overview Programming Sequence To modify a scanner feature (item), the programming bar codes contained in this manual must be scanned in a given sequence depending upon the feature being programmed (as shown in Table 5-1). There are three possible programming sequences: NOTE If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session.
Programming Table 5-1. Programming Sequence SET A ITEM TAG ITEM VALUE END/RESET 1 2 3 SWITCH ENABLE NEW FEATURE SWITCH 1 2 345 6 0 B SWITCH C 5-8 ENABLE NEW FEATURE USING THE FOLLOWING SETTINGS...
LED and Beeper Indicators LED and Beeper Indicators The scanner provides a set of indicators that verify/announce the various scanner functions. If You Make a Mistake... If, during a programming session, you find that you are unsure of the scanner’s settings or wish to reset the scanner’s configuration, use the Return to Factory Settings label below to return the scanner’s configuration to the factory settings. Scanning this label will also reset any changes made during previous programming sessions.
Programming RETURN TO FACTORY SETTINGS Test Mode Use this feature to place the scanner into a testing, or “demo” mode. This special mode disables the scanner interface, meaning that bar code data is not sent out to the host via the scanner interface. This allows the bar code to be scanned continuously without requiring a response from the POS terminal. To return the scanner to normal function, scan the TEST MODE = DISABLE bar code below.
General Scanner Features General Scanner Features Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). To set the Double Read Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Double Read Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Laser Timeout The laser timeout feature sets the time for switching the visible laser diodes (VLDs) off if the scanner is idle. Using this feature can prolong the life of the VLDs. To set the Laser Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Laser Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Motor Timeout The Motor Timeout feature sets the time for automatically switching the motor off when the scanner is not in use. Laser safety requires that the laser switch off before the motor. If you set the motor timeout shorter than the laser timeout, the motor and the laser will both shut off when the motor timeout expires. NOTE To set the Motor Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Programming Motor Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Motor Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Green LED Idle State This feature specifies the state of the green scanner LED when the scanner is idle and ready to read a label. Options are: • Off • On dim To set the LED Idle State: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner Features Scanner Button Options Configure the scanner volume button to one of the following modes of operation: • Enable all functions: Volume, tone, diagnostics and reset. • Enable only volume, tone and reset. • Enable reset only. • Disable all button functions To set the desired Scanner Button Option: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Programming Scanner Button Options — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Power-up Beep Control Specifies the type of audible indication that is made when entering scanner-active mode on power-up. Choices are: • No beep • One beep • Three beeps To set the Power-up Beep: 1. Scan the SWITCH bar code. 2. Scan your selection from the three bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Power-up Beep Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Good Read Beep Control This feature enables/disables scanner beep upon successfully decoding of a label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the two bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Good Read Beep Frequency Adjusts the scanner’s good read beep to sound at low, medium, or high frequency (controls the beeper’s pitch/tone). • Low = 660 Hz • Medium = 866 Hz • High = 1600 Hz To set the Good Read Beep Frequency: 1. Scan the SWITCH bar code. 2. Scan your selection from the three bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
General Scanner Features Good Read Beep Frequency — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Good Read Beep Length Specifies the duration of a good read beep. To set the good read beep length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GOOD READ BEEP LENGTH. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired good read beep length setting.
General Scanner Features Good Read Beep Volume Selects the beeper volume upon a good read beep. There are four selectable volumes, with each volume incrementing upward from the previous decibel level: • 0 = Lowest Volume • 1 = Medium-Low Volume • 2 = Medium Volume • 3 = High Volume To set the Good Read Beep Volume: 1. Scan the SWITCH bar code. 2. Scan your selected volume bar code from this or the following pages.
Programming Good Read Beep Volume — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Good Read Beep Volume — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Good Read When to Indicate This feature specifies when the scanner will provide indication (beep and/ or flash its green LED) upon successfully reading a bar code. • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active The “Indicate after CTS goes inactive...” mode applies to RS-232 STD and RS-232 WN interfaces only. If set to this mode in other interfaces, “Indicate after decode” mode will be implemented.
General Scanner Features Good Read When to Indicate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming EAS Active State Specifies the active state polarity of EAS (Electronic Article Surveillance); the inactive state is its opposite polarity. EAS output goes active during the good read of a bar code, allowing the EAS device to deactivate a tag on the product. To set the EAS Active State: 1. Scan the SWITCH bar code. 2. Scan bar code below representing the desired setting.
General Scanner Features EAS Timeout Specifies the amount of time that an EAS (Electronic Article Surveillance) signal is held in its active state for a good read. To set the EAS Timeout: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS TIMEOUT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Aux Port Mode Selects the usage for the scanner’s optional auxilliary port. The choices listed below are mutually exclusive (only one option can be active at a time). • Disabled — Port is inactive • External Handheld Input — Supports PSC® handheld scanners (QuickScan 1000, QuickScan 6000, PowerScan) as well as other models such as the Symbol® HotShot. Call your dealer for more information about supported devices.
General Scanner Features Aux Port Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2.
Interface Related Features Interface Related Features Interface Type Specifies the current scanner interface.
Programming Interface Type — continued To select the desired interface: CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features RS-232 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Programming RS-232 Wincor-Nixdorf Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features RS-232 Single Cable Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Programming IBM Port 17 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features IBM USB Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Programming USB Keyboard Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features PC Keyboard Wedge Interface Selection This scanner supports a variety of PC Keyboard interfaces. The table below defines the different interface selections. Scan the corresponding bar code starting on page 5-46 to select the desired keyboard interface.
Programming PC Keyboard Wedge Interface Types Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features PC Keyboard Wedge Interface Types — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Programming PC Keyboard Wedge Interface Types — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features PC Keyboard Wedge Interface Types — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Programming PC Keyboard Wedge Interface Types — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Maximum Host-Transmitted Message Length Specifies the maximum number of data characters allowed in messages transmitted to the host. To set the Maximum Host-Transmitted Message Length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MAXIMUM HOST-TRANSMITTED MESSAGE LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Number of Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted.
Interface Related Features Global Prefix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the prefix that is added to beginning of label transmission. To specify the Global Prefix Character(s): 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GLOBAL PREFIX below. You’ll need to cover any unused bar codes to ensure the scanner reads only the bar code you intend to scan. 3.
Programming Global Prefix — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Interface Related Features Global Suffix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the suffix that is added to end of a label transmission. Three standard options are available below. Contact your dealer for other alternate settings for this feature. • No Global Suffix • CR — Carriage Return • CR LF — Carriage Return, Line Feed To set the Global Suffix: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. 3.
Programming Global Suffix — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM Features IBM Features IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B. When enabled, this feature has no effect on IBM Port 17. NOTE To enable/disable the IBM Transmit Labels in Code 39 Format feature: 1. Scan the SWITCH bar code. 2.
Programming IBM USB Scanner Device Type The IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB POS, you may need to change this setting to enable all scanners to communicate. Options are: • Fixed Position Scanner • Handheld Scanner To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
RS-232 Features RS-232 Features RS-232 Baud Rate This feature selects the baud rate required for sending and receiving data. Single cable interfaces are limited to Baud Rate selections up to 19200. They cannot communicate at Baud Rates of 38400 and up. NOTE To specify the RS-232 Baud Rate: 1. Scan the SWITCH bar code. 2. Scan the desired baud rate from the bar codes below and on the immediately following pages.
Programming RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Number of Data Bits Specifies number of data bits required for sending and receiving data. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired Data Bit setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RS-232 Number of Stop Bits Specifies number of stop bits required for sending and receiving data. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired Stop Bit setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Parity Specifies parity required for sending and receiving data. Options for this setting are: • RS-232 PARITY = NONE • RS-232 PARITY = EVEN • RS-232 PARITY = ODD To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or on the following pages representing the desired Parity setting. You’ll need to cover any unused bar codes, as well as facing pages to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming RS-232 Parity — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Hardware Control Enables/disables use of the RS-232 CTS signal for flow control and/or scan control. Options are: • Disable — The scanner transmits to the host regardless of any activity on the CTS line. • Enable CTS Flow Control — The CTS signal controls transmission of data to the host. • Enable CTS Scan Control — The CTS line must be active for scanner to read and transmit data.
Programming RS-232 Hardware Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Intercharacter Delay Specifies delay between the end of one character and the beginning of the next in 10-millisecond increments. To set the RS-232 Intercharacter Delay: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 INTERCHARACTER DELAY. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming RS-232 Software Flow Control Enables/disables RS-232 Flow Control using XON/ XOFF characters. This item will be ignored when the feature, RS-232 NAK Character, is enabled NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Host Echo When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary.
Programming RS-232 Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host. • 0 - 100 = Time in 10-millisecond increments. To set the Host Echo Quiet Interval: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 HOST ECHO QUIET INTERVAL.
RS-232 Features RS-232 Ignore Host Commands When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels. For normal operation of the interface, disable this feature. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming RS-232 TTL Specifies whether RS-232 interface provides TTL levels on the output pins TxD and RTS. Choices are: • Normal RS-232 levels • TTL levels To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 TTL Invert Enables/disables inversion of TTL. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RS-232 Beep on ASCII BEL Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex). • Disable • Enable To enable/disable this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Beep on Not on File Select for the host to beep (or not) when a not-on-file condition is detected by the host. This feature is also applicable to single cable RS-232.
Programming RS-232 ACK NAK Enable This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
RS-232 Features RS-232 ACK NAK Enable — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming RS-232 ACK Character This feature specifies which ASCII character will be used as an ACK character. NOTE DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits. To specify the RS-232 ACK Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 ACK Character below.
RS-232 Features RS-232 NAK Character This feature specifies which ASCII character will be used as a NAK character. NOTE DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits. To specify the RS-232 NAK Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 NAK Character below.
Programming RS-232 Retry on ACK NAK Timeout This option specifies the action scanner performs on expiration of the RS232 ACK NAK Timeout Value. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 ACK NAK Timeout Value This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. • 0 = Infinite timeout • 1 - 75 = Timeout in 200-millisecond increments To set the ACK NAK Timeout Value: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 ACK NAK TIMEOUT VALUE. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming RS-232 ACK NAK Retry Count This feature sets the number of times for the scanner to retry a label transmission under a retry condition. To set the RS-232 ACK NAK Retry Count: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 ACK NAK RETRY COUNT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Features RS-232 ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. • Ignore Errors (recommended setting) • Assume ACK (risk of lost label data) • Assume NAK (risk of duplicate label) To select the option for RS-232 ACK NAK Error Handling: 1. Scan the SWITCH bar code. 2.
Programming RS-232 ACK NAK Error Handling — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Label ID Control This feature specifies whether or not Label IDs are transmitted to the host and if so, whether to attach them as a prefix or suffix.
Programming RS-232 Label ID Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 Options Single Cable RS-232 Options The RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces.
Programming Single Cable RS-232 RTS CTS Selection Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the configuration values state, to determine when to send label data.
Single Cable RS-232 Options Single Cable RS-232 RTS CTS Selection — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Single Cable RS-232 RTS CTS Selection — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 Options Single Cable RS-232 Use BCC Enables/disables the ability of the scanner to use BCC. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Single Cable RS-232 Use ACK/NAK Enables/disables the ability of the scanner to use ACK/NAK. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Options Single Cable RS-232 Use STX Enables/disables the ability of the scanner to use STX. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Set Single Cable RS-232 STX Character This feature selects the STX character. To specify the STX Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET SINGLE CABLE RS-232 STX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character.
Single Cable RS-232 Options Single Cable RS-232 Use ETX Enables/disables the ability of the scanner to use ETX. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Set Single Cable RS-232 ETX Character Allows selection of the ETX character. To specify the ETX Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET SINGLE CABLE RS-232 ETX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character.
PC Keyboard Wedge and USB Keyboard Interfaces PC Keyboard Wedge and USB Keyboard Interfaces This section contains the following PC Keyboard Wedge and USB Keyboard Interface parameters in the order listed: • Connect to a Laptop/No Keyboard Attached (PC Keyboard Wedge ONLY) • Send Control/Function Characters • Caps Lock • Country Mode • Keyboard Wedge Intercharacter Delay (PC Keyboard Wedge ONLY) • Quiet Interval (PC Keyboard Wedge ONLY) If the transmission parameters are configured such that a l
Programming Connect to a Laptop/No Keyboard Attached This feature applies to PC Keyboard Wedge ONLY. NOTE If no keyboard is attached, the scanner must provide the acknowledge signal to the PC. In this case, enable the "Laptop/No External Keyboard" mode. If a keyboard is attached, enable "Keyboard Attached." Laptop (no external keyboard) — provides the acknowledge signal to the PC when the scanner is connected to a laptop computer or when the scanner is operated with no external keyboard.
PC Keyboard Wedge and USB Keyboard Interfaces Send Control/Function Characters Options for this feature are: Send Control Characters — transmits all ASCII characters except NUL (00h) . Disable Control Characters — disabling this feature limits transmis- sion of ASCII characters to the following: • Only ASCII characters between 20h..127h, plus.
Programming Send Control/Function Characters — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
PC Keyboard Wedge and USB Keyboard Interfaces Caps Lock Three caps lock settings are available. These are: Caps Lock Off — •sends character data to the host in normal format. Caps Lock On — •sends character data to the host in reverse case (a.z) = (A.Z) (A.Z) = (a.z) Use this feature if your keyboard's caps lock key is on. Caps Lock = Shift-Lock — sends character data (to the host) in shifted case. Use this feature if you choose to use the keyboard with the shift lock key left on.
Programming Caps Lock — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
PC Keyboard Wedge and USB Keyboard Interfaces Country Mode The following country/languages can be selected when configured for wedge I/F Type E or USB Keyboard: • USA • France • Portugal • Belgium • Germany • Spain • Britain • Italy • Sweden • Denmark • Norway • Switzerland • Japanese 106-Key Scan the bar code below to select the desired country.
Programming Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. COUNTRY MODE: BRITAIN .
PC Keyboard Wedge and USB Keyboard Interfaces Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. COUNTRY MODE: FRANCE .
Programming Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. COUNTRY MODE: ITALY .
PC Keyboard Wedge and USB Keyboard Interfaces Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. COUNTRY MODE: PORTUGAL .
Programming Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. COUNTRY MODE: SWEDEN .
PC Keyboard Wedge and USB Keyboard Interfaces Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Keyboard Wedge Intercharacter Delay This feature applies to PC Keyboard Wedge ONLY. NOTE Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner. Use these labels to select the desired Intercharacter Delay.
PC Keyboard Wedge and USB Keyboard Interfaces Keyboard Wedge Intercharacter Delay — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. KEYBOARD WEDGE INTERCHARACTER DELAY = 20 MILLISECONDS .
Programming Keyboard Wedge Intercharacter Delay — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. KEYBOARD WEDGE INTERCHARACTER DELAY = 40 MILLISECONDS .
PC Keyboard Wedge and USB Keyboard Interfaces Keyboard Wedge Intercharacter Delay — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. KEYBOARD WEDGE INTERCHARACTER DELAY = 80 MILLISECONDS .
Programming Quiet Interval This feature applies to PC Keyboard Wedge ONLY. NOTE Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host. QUIET INTERVAL = 10 MILLISECONDS .
PC Keyboard Wedge and USB Keyboard Interfaces Quiet Interval — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. QUIET INTERVAL = 50 MILLISECONDS .
Programming Quiet Interval — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. QUIET INTERVAL = 200 MILLISECONDS .
PC Keyboard Wedge and USB Keyboard Interfaces Quiet Interval — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Symbology Programming If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Changing an interface type resets ALL other configuration items — including symbology programming — to the factory default for that interface type.) NOTE UPC-A Enable Enables/disables the ability of the scanner to decode UPC-A labels. To set this feature: 1. Scan the SWITCH bar code. 2.
UPC-A Enable UPC-A Number System Character Transmission Enables/disables transmission of a UPC-A number system character. This feature MUST be enabled for IBM interfaces for proper function. NOTE This item is ignored when the advanced feature, Full Label Edit, is enabled. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming UPC-A Check Character Transmission Enables/disables transmission of a UPC-A check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Enable Expand UPC-A to EAN-13 Enables/disables expansion of UPC-A labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming UPC/EAN AIM ID This feature enables/disables transmission of the UPC/EAN AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Enable UPC-A Label ID This feature specifies a UPC-A label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Programming UPC-A 2-Digit Supplemental Label ID This feature specifies a UPC-A 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 2-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-A Enable UPC-A 5-Digit Supplemental Label ID This feature specifies a UPC-A 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 5-DIGIT SUPPLEMENTAL LABEL ID below.
Programming UPC-A 128 Supplemental Label ID This feature specifies a UPC-A 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 128 SUPPLEMENTAL LABEL ID below.
UPC-E Enable UPC-E Enable Enables/disables the ability of the scanner to decode UPC-E labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming UPC-E Number System Character Transmission Enables/disables transmission of a UPC-E number system character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
UPC-E Enable UPC-E Check Character Transmission Enables/disables transmission of a UPC-E check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Expand UPC-E to UPC-A Enables/disables expansion of UPC-E labels to UPC-A. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable Expand UPC-E to EAN-13 Enables/disables expansion of UPC-E labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming UPC-E Label ID This feature specifies a UPC-E label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
UPC-E Enable UPC-E 2-Digit Supplemental Label ID This feature specifies a UPC-E 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 2-DIGIT SUPPLEMENTAL LABEL ID below.
Programming UPC-E 5-Digit Supplemental Label ID This feature specifies a UPC-E 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 5-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-E Enable UPC-E 128 Supplemental Label ID This feature specifies a UPC-E 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 128 SUPPLEMENTAL LABEL ID below.
Programming EAN-13 Enable Enables/disables the ability of the scanner to decode EAN/JAN-13 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 Enable EAN-13 First Character Transmission Enables/disables transmission of EAN/JAN-13 first character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming EAN-13 Check Character Transmission Enables/disables transmission of an EAN/JAN-13 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 Enable EAN-13 ISBN Conversion Enable Enables/disables conversion of EAN/JAN-13 labels starting with 978 to Bookland ISBN labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming EAN 13 Label ID This feature specifies an EAN 13 label ID to be added to bar code data. To set this feature: The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 13 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
EAN-13 Enable EAN-13 2-Digit Supplemental Label ID This feature specifies an EAN-13 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 2-DIGIT SUPPLEMENTAL LABEL ID below.
Programming EAN-13 5-Digit Supplemental Label ID This feature specifies an EAN-13 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 5-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-13 Enable EAN-13 128 Supplemental Label ID This feature specifies an EAN-13 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 128 SUPPLEMENTAL LABEL ID = DISABLE below.
Programming Bookland AIM ID This feature enables/disables transmission of the Bookland AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 Enable Bookland Label ID This feature specifies a Bookland label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET BOOKLAND LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Programming EAN-8 Enable Enables/disables the ability of the scanner to decode EAN/JAN-8 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable EAN-8 Check Character Transmission Enables/disables transmission of an EAN/JAN-8 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Expand EAN-8 to EAN-13 Enables/disables expansion of EAN/JAN-8 labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable EAN 8 Label ID This feature specifies an EAN 8 label ID to be added to bar code data. To set this feature: The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 8 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Programming EAN-8 2-Digit Supplemental Label ID This feature specifies an EAN-8 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 2-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-8 Enable EAN-8 5-Digit Supplemental Label ID This feature specifies an EAN-8 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 5-DIGIT SUPPLEMENTAL LABEL ID below.
Programming EAN-8 128 Supplemental Label ID This feature specifies an EAN-8 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 128 SUPPLEMENTAL LABEL ID below.
EAN-8 Enable EAN-8 Decoding Levels Decoding levels allow the decoder to be set to perform at one of four selectable levels: • Very Conservative — Slower scan time, virtually eleminates misreads. The most secure setting. • Slightly More Aggressive — Faster scanning, more aggressive, yet minimizes misreads. • Moderately Aggressive — Even faster scanning, even more aggressive. • Very Aggressive — Fastest scan speed, most aggressive.
Programming EAN-8 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Enable EAN-8 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Other UPC/EAN Options The following pages contain other selectable features for UPC/EAN symbologies: 5-158 • UPC/EAN Reconstruction • Price Weight Check • Enable EAN Two Label • Addons • UPC-A and EAN-13 Decoding Levels Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Other UPC/EAN Options UPC/EAN Reconstruction Enables/disables the ability of the scanner to decode a class of UPC/EAN labels with voids. The label voids may be caused by printing defects or physical damage. This feature may be helpful in environments with instore printed labels. Enabling this feature increases the potential of misreads. CAUTION To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming Price Weight Check Enables/disables calculation and verification of price/weight check digits. Applies to all UPC-A and EAN/JAN-13 labels with eligible1 Number System/First Character digits. Options are: • Disable • 4-digit price/weight • 5-digit price/weight • 4-digit European price/weight • 5-digit European price/weight To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages.
Other UPC/EAN Options Price Weight Check — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Price Weight Check — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Enable EAN Two Label Enables/disables the ability of the scanner to decode EAN two-label pairs. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Addons The scanner is capable of processing different types of addon codes, including: • 2-Digit Supplemental • 5-Digit Supplemental Options are provided on the following pages for your convenience: • Disable all addons — The scanner will not look for or read addons. • Optional 2-Digit and 5-Digit Supplemental — Bar codes can be read which include 2-Digit or 5-Digit Supplementals, however, it is not required that addons be included in bar codes.
Other UPC/EAN Options Addons — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming UPC-A and EAN-13 Decoding Levels Decoding levels allow the decoder to be set to perform at one of four selectable levels: • Very Conservative — Slower scan time, virtually eleminates misreads. The most secure setting. • Slightly More Aggressive — Faster scanning, more aggressive, yet minimizes misreads. • Moderately Aggressive — Even faster scanning, even more aggressive. • Very Aggressive — Fastest scan speed, most aggressive.
Other UPC/EAN Options UPC-A and EAN-13 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming UPC-A and EAN-13 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GTIN Enable GTIN Enable Enables/Disables the ability to convert UPCE, UPCA, EAN8, and EAN13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN bar code. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming GTIN Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN LABEL ID below.
GTIN Enable GTIN 2-Digit Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 2-digit supplemental addon bar code labels are converted. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN 2-DIGIT SUPPLEMENTAL LABEL ID below.
Programming GTIN 5-Digit Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 5-digit supplemental addon bar code labels are converted. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN 5-DIGIT SUPPLEMENTAL LABEL ID below.
GTIN Enable GTIN Code 128 Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and Code 128 supplemental addon bar code labels are converted The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN CODE 128 SUPPLEMENTAL LABEL ID below.
Programming RSS-14 Enable Enables/disables the ability of the scanner to decode RSS-14 labels. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RSS-14 Enable RSS-14 Check Character Transmission Enables/disables transmission of the RSS-14 check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RSS-14/EAN-128 Emulation Enables/disables the ability of RSS-14 to be transmitted as EAN-128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS-14 Enable RSS-14 2D Component Enable When this feature is enabled, the software will not decode an RSS-14 bar code with a 2D component associated with it, and the 2D component will be discarded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RSS-14 AIM ID This feature enables/disables transmission of the RSS-14 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS-14 Enable RSS-14 Label ID This feature specifies an RSS-14 label ID to be added to bar code data. To set this feature: The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS-14 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.
Programming RSS Expanded Enable Enables/disables the ability of the scanner to decode RSS-Expanded labels. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
RSS Expanded Enable RSS Expanded EAN-128 Emulation Enables/disables EAN 128 emulation for RSS Expanded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RSS Expanded 2D Component Enable When this feature is enabled, the software will not decode an RSS Expanded bar code with a 2D component associated with it, and the 2D component will be discarded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RSS Expanded Enable RSS Expanded AIM ID This feature enables/disables transmission of the RSS Expanded AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RSS Expanded Label ID This feature specifies an RSS Expanded label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
RSS Expanded Enable RSS Expanded Length Control This feature specifies either variable-length or fixed-length decoding for RSS Expanded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming RSS Expanded Maximum Label Length This feature specifies the maximum allowable length of an RSS Expanded label. Length in this case includes check and data characters. This applies when RSS Expanded Length Control is set to variable-length decoding. NOTE Maximum Label Length should be greater than or equal to Minimum Label Length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED MAXIMUM LABEL LENGTH below.
RSS Expanded Enable RSS Expanded Minimum Label Length This feature specifies the minimum allowable length of an RSS Expanded label. Length in this case includes check and data characters. This applies when RSS Expanded Length Control is set to variablelength decoding. NOTE Minimum Label Length should be less than or equal to Maximum Label Length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED MINIMUM LABEL LENGTH below.
Programming RSS Expanded Fixed Length 1 This feature specifies RSS Expanded first fixed length. This applies when RSS Expanded Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RSS Expanded Enable RSS Expanded Fixed Length 2 This feature specifies RSS Expanded second fixed length. This applies when RSS Expanded Length Control is set to fixedlength decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED FIXED LENGTH 2 below.
Programming Code 39 Enable Enables/disables the ability of the scanner to decode Code 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Start Stop Character Transmission Enables/disables transmission of Code 39 start and stop characters. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Code 39 Check Character Calculation Enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in label is treated as a data character. If check calculation is disabled, the risk is increased that a misread can occur. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Code 39 Enable Code 39 Check Character Transmission Enables/disables transmission of optional Code 39 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Code 39 Full ASCII Enables/disables the ability of the scanner to translate to Code 39 full ASCII labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 AIM ID This feature enables/disables transmission of the Code 39 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Code 39 Label ID This feature specifies a Code 39 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 39 Enable Code 39 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Code 39 Maximum Label Length This feature specifies the maximum allowable length of a Code 39 label. Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 MAXIMUM LABEL LENGTH below.
Code 39 Enable Code 39 Minimum Label Length This feature specifies the minimum allowable length of a Code 39 label. Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 MINIMUM LABEL LENGTH below.
Programming Code 39 Fixed Length 1 This feature specifies Code 39 first fixed length. This applies when Code 39 Length Control is set to fixed-length decoding. NOTE The minimum decodable length is four when an optional check character is present. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 39 Enable Code 39 Fixed Length 2 This feature specifies Code 39 second fixed length. This applies when Code 39 Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00, then Fixed Length 1 will apply To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Pharmacode 39 Enable Pharmacode 39 Enable Enables/disables the ability of the scanner to decode Italian Pharmacode 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Pharmacode 39 Start Stop Character Transmission Enables/ disables transmission of start and stop characters for Pharmacode 39. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Pharmacode 39 Enable Pharmacode 39 Check Character Transmission Enables/disables transmission of Pharmacode 39 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Pharmacode 39 Label ID This feature specifies a Pharmacode 39 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET PHARMACODE 39 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Enable Enables/disables the ability of the scanner to decode Code 128 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Code 128 Transmit Function Characters Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4. Disabled is the recommended setting for all interfaces. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Convert Code 128 to Code 39 Enables/disables conversion of Code 128 labels to Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Code 128 AIM ID This feature enables/disables transmission of the Code 128 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Code 128 Label ID This feature specifies a Code 128 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Programming Code 128 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Code 128 Maximum Label Length This feature specifies the maximum allowable length of a Code 128 label. Length in this case includes function characters and data characters, but does not include function code change or check character. This feature applies when Code 128 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming Code 128 Minimum Label Length This feature specifies the minimum allowable length of a Code 128 label. Length in this case includes function characters and data characters, but does not include function code change or check character. This feature applies when Code 128 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Code 128 Enable Code 128 Fixed Length 1 This feature specifies Code 128 first fixed length. This applies when Code 128 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Code 128 Fixed Length 2 This feature specifies Code 128 second fixed length. This applies when Code 128 Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Stitching Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Programming EAN-128 Enable Enables/disables the ability of the scanner to decode EAN-128 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-128 Enable EAN 128 AIM ID This feature enables/disables transmission of the EAN 128 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming EAN 128 Label ID This feature specifies an EAN 128 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 OF 5) Enable Interleaved 2 of 5 (I 2 OF 5) Enable Enables/disables the ability of the scanner to decode Interleaved 2 of 5 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming I 2 of 5 Check Character Calculation Enables/disables calculation and verification of an optional Interleaved 2 of 5 check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Interleaved 2 of 5 (I 2 OF 5) Enable I 2 of 5 Check Character Transmission Enables/disables transmission of an optional Interleaved 2 of 5 check character. This feature applies only when I 2 of 5 Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming I 2 of 5 AIM ID This feature enables/disables transmission of the I 2 of 5 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Interleaved 2 of 5 (I 2 OF 5) Enable I 2 of 5 Label ID This feature specifies an I 2 of 5 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 of 5 LABEL ID below.
Programming I 2 of 5 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for I 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Interleaved 2 of 5 (I 2 OF 5) Enable I 2 of 5 Maximum Label Length This feature specifies the maximum allowable length of an I 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming I 2 of 5 Minimum Label Length This feature specifies the minimum allowable length of an I 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 MINIMUM LABEL LENGTH below.
Interleaved 2 of 5 (I 2 OF 5) Enable I 2 of 5 Fixed Length 1 This feature specifies I 2 of 5 first fixed length. This applies when I 2 of 5 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming I 2 of 5 Fixed Length 2 This feature specifies I 2 of 5 second fixed length. This applies when I 2 of 5 Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 OF 5) Enable I 2 of 5 Stitching Enables/disables stitching for I 2 of 5 labels. When parts of an I 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Programming Codabar Enable Enables/disables the ability of the scanner to decode Codabar labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Start Stop Character Transmission Enables/disables transmission of Codabar start and stop characters. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Codabar Start Stop Character Set This feature selects the format of transmitted Codabar start/stop characters. Options are: • ABCD/TN* E • ABCD/ABCD • abcd/tn* e • abcd/abcd To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or from the following page representing the desired option. You’ll need to cover any unused bar codes and facing pages to ensure that the scanner reads only the bar code you intend to scan. 3.
Codabar Enable Codabar Start Stop Character Set — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Programming Codabar Start Stop Character Match Enables/disables the requirement that start and stop characters match. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Check Character Calculation Enables/disables calculation and verification of an optional Codabar check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming Codabar Check Character Transmission Enables/disables transmission of an optional Codabar check character. Applies only when Codabar Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Codabar Enable Codabar AIM ID This feature enables/disables transmission of the Codabar AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Codabar Label ID This feature specifies a Codabar label ID to e added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Codabar Enable Codabar Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Codabar. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Codabar Maximum Label Length This feature specifies the maximum allowable length of a Codabar label. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Codabar Enable Codabar Minimum Label Length This feature specifies the minimum allowable length of a Codabar label. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming Codabar Fixed Length 1 This feature specifies Codabar first fixed length. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to fixedlength decoding. NOTE Decodable length is four when the optional check character is present. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR FIXED LENGTH 1 below.
Codabar Enable Codabar Fixed Length 2 This feature specifies Codabar second fixed length. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to fixedlength decoding. NOTE Decodable length is four when the optional check character is present. If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Code 93 Enable Code 93 Enable Enables/disables the ability of the scanner to decode Code 93 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Code 93 AIM ID This feature enables/disables transmission of the Code 93 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Enable Code 93 Label ID This feature specifies a Code 93 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Programming Code 93 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 93. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Enable Code 93 Maximum Label Length This feature specifies the maximum allowable length of a Code 93 label. Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming Code 93 Minimum Label Length This feature specifies the minimum allowable length of a Code 93 label. Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 MINIMUM LABEL LENGTH below.
Code 93 Enable Code 93 Fixed Length 1 This feature specifies Code 93 first fixed length. This applies when Code 93 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming Code 93 Fixed Length 2 This feature specifies Code 93 second fixed length. This applies when Code 93 Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 93 Enable Code 93 Stitching Enables/disables stitching for Code 93 labels. When parts of a Code 93 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Programming MSI/Plessey Enable Enables/disables the ability of the scanner to decode MSI/Plessey labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Enable MSI/Plessey Check Character Calculation Enables/disables calculation and verification of optional MSI/Plessey check characters. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming MSI/Plessey Number of Check Characters Specifies number of MSI/Plessey check characters to be calculated and verified. Check characters are always modulus 10. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired number of MSI/ Plessey check characters to be calculated and verified. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Enable MSI/Plessey Check Character Transmission Enables/disables transmission of optional MSI/Plessey check characters. This feature applies only when MSI/Plessey Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming MSI/Plessey AIM ID This feature enables/disables transmission of the MSI/Plessey AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Enable MSI/Plessey Label ID This feature specifies an MSI/Plessey label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.
Programming MSI/Plessey Length Control This feature specifies whether variable-length or fixed-length decoding will be set for MSI/Plessey. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Enable MSI/Plessey Maximum Label Length This feature specifies the maximum allowable length of an MSI/Plessey label. Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This feature applies when MSI/Plessey Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming MSI/Plessey Minimum Label Length This feature specifies the minimum allowable length of an MSI/Plessey label. Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This applies when MSI/Plessey Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
MSI/Plessey Enable MSI/Plessey Fixed Length 1 This feature specifies MSI/Plessey first fixed length. This applies when MSI/Plessey Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Programming MSI/Plessey Fixed Length 2 This feature specifies MSI/Plessey second fixed length. This applies when MSI/Plessey Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Enable MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/ Plessey bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Programming Standard 2 of 5 Enable Enables/disables the ability of the scanner to decode Standard 2 of 5 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation Enables/disables calculation and verification of an optional Standard 2 of 5 check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check character in a bar code is treated as data character. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Programming Standard 2 of 5 Check Character Transmission Enables/disables transmission of an optional Standard 2 of 5 check character. This feature applies only when Standard 2 of 5 Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Standard 2 of 5 Enable Standard 2 of 5 AIM ID This feature enables/disables transmission of the Standard 2 of 5 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Standard 2 of 5 Label ID This feature specifies an Standard 2 of 5 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 of 5 LABEL ID below.
Standard 2 of 5 Enable Standard 2 of 5 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Standard 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Programming Standard 2 of 5 Maximum Label Length This feature specifies the maximum allowable length of a Standard 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when Standard 2 of 5 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Standard 2 of 5 Enable Standard 2 of 5 Minimum Label Length This feature specifies the minimum allowable length of an Standard 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when Standard 2 of 5 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Programming Standard 2 of 5 Fixed Length 1 This feature specifies Standard 2 of 5 first fixed length. This applies when Standard 2 of 5 Length Control is set to fixedlength decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Standard 2 of 5 Enable Standard 2 of 5 Fixed Length 2 This feature specifies Standard 2 of 5 second fixed length. This applies when Standard 2 of 5 Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 FIXED LENGTH 2 below.
Programming Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. This applies when Standard 2 of 5 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2.
Appendix A LED/Beeper Indications & Controls Figure A-1 shows the operator’s controls and indicators for both models. The descriptions following identify the use or function of each component. Figure A-1.
Volume/Tone Push Button The Volume/Tone Push Button also performs multiple functions depending upon the duration of time it is pressed: NOTE Volume changes made using the Volume/Tone Push Button are lost when the scanner is powered-down and are reset to the configured setting. If you wish to permanently change the volume, use the special programming labels in the Product Reference Guide. Table A-1.
Green LED Indicator The green LED indicates scanner status as shown in the table below. Table A-2.
NOTES A-4 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Appendix B Cable Information Introduction The following pages contain pinout information, enabling you to create standard interface cables for use in interconnecting the scanner, external handheld scanner, and POS terminal. General Specifications Wire Requirements • Cable length should not exceed 15 feet. • Wire gauge = Standard for RJ-45 connectors (28-26 AWG). • If run exceeds 15 feet, we recommend 26 AWG wire size.
RS-232 Cable Pinout Scanner Connector Hardware RJ45, 10 Position Cable Pinout Table B-1.
IBM Cable Pinout Scanner Connector Hardware RJ45, 10 Position Cable Pinout Table B-2 Product Reference Guide PIN # FUNCTION DESCRIPTION 1 +5V pullup 2 N/C No Connection 3 N/C No Connection 4 Serial I/O B 5 N/C 6 Serial I/O A 7 N/C 8 +5V out +5V out 9 Ground Signal Ground 10 N/C No Connection +5V pullup Serial Data No Connection Serial Data + No Connection B-3
IBM USB Cable Pinout Scanner Connector Hardware RJ45, 10 Position Cable Pinout Table B-3 B-4 PIN # FUNCTION DESCRIPTION 1 +5V pullup 2 N/C No Connection 3 N/C No Connection 4 USB D- 5 N/C 6 USB D+ 7 N/C 8 +5V out 9 GND Signal Ground 10 N/C No Connection +5V pullup USB DNo Connection USB D+ No Connection +5V out Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Auxiliary Port External Handheld Input Connector Hardware RJ45, 10 Position Cable Pinout Table B-4 PIN # FUNCTION 1 DTR Data Terminal Ready 2 CTS in Clear To Send (input) 3 N/C No Connection - Reserved 4 RTS out Request To Send (output) 5 RxD in Receive Data (Input) 6 TxD out Transmit Data (output) 7 ~EAS_GOOD READ Special use Good Read 8 +5V out (500mA max) +5V out 9 GND 10 SPKR OUT Product Reference Guide DESCRIPTION Signal Ground Speaker Out B-5
NOTES B-6 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Appendix C Keypad Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Appendix D Host Commands Accepting Commands from an RS-232 Scanner Host The scanner responds to the following RS-232 commands: COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable Scanner D 0x44 Reset Scanner R 0x52 Not On File Indication F 0x46 Long series of beeps Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good Read Tone 0x01 Beeps regardless of beep setting Bel 0x07 Force Good Read Tone Identification request i 0x69 Returns long responsea Health
NOTES D-2 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Appendix E Factory Defaults The following table provides a listing of the most common factory settings for the interfaces shown. Table E-1. Factory Default Settings Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Double Read Timeout 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) Laser Timeout 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Good Read When to Indicate 0 (after decode) 0 (after decode) 0 (after decode) 0 (after decode) 0 (after decode) 0 (after decode) 0 (after decode) 0 (after decode) EAS Active State 0 (active low) 0 (active low) 0 (active low) 0 (active low) 0 (active low) 0 (active low) 0 (active low) 0 (active low) EAS Timeout 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) Aux Port Mode
Table E-2 Aux RS-232 WincorNixdorf Single Cable USB Keybd PC KBW Global Prefix ("") ("") ("") ("") ("") ("") Global Suffix 0D00 ("\0D") 0D00 ("\0D") 0D00("") ("") 0D00 ("\0D") 0D00 ("\0D") IBM Transmit Labels in Code 39 Format IBM 17 0 (disable) IBM USB Scanner Device Type 0 (fixed scanner) RS-232 Baud Rate 1 (9600) 1 (9600) 1 (9600) 1 (9600) RS-232 Number of Data Bits 1 (8 data bits) 1 (8 data bits) 1 (8 data bits) 0 (7 data bits) RS-232 Number of Stop Bits 0 (1 stop bit
Table E-2 WincorNixdorf Aux RS-232 RS-232 TTL Invert 0 (disable) 0 (disable) RS-232 Beep on ASCII BEL 0 (disable) 0 (disable) 0 (disable) RS-232 Beep on Not on File 1 (enable) 1 (enable) 1 (enable) RS-232 ACK NAK Enable 0 (disable) 0 (disable) 0 (disable) RS-232 ACK Character 6 (ACK) 6 (ACK) 6 (ACK) RS-232 NAK Character 21 (NAK) 21 (NAK) 21 (NAK) RS-232 Retry on ACK NAK Timeout 1 (enable) 1 (enable) 1 (enable) RS-232 ACK NAK Timeout Value 1 (200ms) 1 (200ms) 1 (200ms) RS-23
Table E-2 Aux RS-232 Single Cable RS-232 Use STX WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW 1 (enable) Set Single Cable RS-232 STX Character 83 (S) Single Cable RS-232 Use ETX 1 (enable) Set Single Cable RS-232 ETX Character 13 (CR) UPC-A Enable 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) UPC-A Number System Character Transmission 0 (disable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enabl
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW UPC-E Enable 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) UPC-E Number System Character Transmission 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) UPC-E Check Character Transmission 0 (disable) 0 (disable) 0 (disable) 0 (disable) 1 (enable) 1 (enable) 0 (disable) 0 (disable) Expand UPC-E to UPC-A 0 (disable)
Table E-2 Aux RS-232 WincorNixdorf Single Cable USB Keybd PC KBW EAN 13 Label ID 4600("F") 4600("F") 4100("A") 4600("F") 4600("F") 4600("F") EAN-13 2-Digit Supplemental Label ID 4600("F") 4600("F") 4100("A") 4600("F") 4600("F") 4600("F") EAN-13 5-Digit Supplemental Label ID 4600("F") 4600("F") 4100("A") 4600("F") 4600("F") 4600("F") EAN-13 128 Supplemental Label ID 4600("F") 4600("F") 4100("A") 4600("F") 4600("F") 4600("F") Bookland AIM ID 0 (disable) 0 (disable) 0 (disa
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Price Weight Check 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Enable EAN Two Label 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Addons Disable All Disable All Disable All Disable All Disable All Disable All Disable All Disable All RSS-14 Enable 0 (disable) 0 (disable) 0 (disable) 0 (disab
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW RSS Expanded 2D Component Enable 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) RSS Expanded AIM ID 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 5258 ("RX") 5258 ("RX") 4500 ("E") 5258 ("RX") 5258 ("RX") 5258 ("RX") 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) RSS Expande
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Code 39 Check Character Transmission 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) Code 39 Full ASCII 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Code 39 AIM ID 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Code 39 Label ID 2A00 ("*") 2A00 ("*") 4D00 ("M") 4231 ("B1") 2A00 ("*") 2A00 (
Table E-2 Aux RS-232 WincorNixdorf Single Cable USB Keybd PC KBW Pharmacode 39 Label ID 4100("A") 4100("A") 4100("A") 4100("A") 4100("A") 4100("A") Code 128 Enable 1 (enable) 1 (enable) 0 (disable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) Code 128 Transmit Function Characters 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Convert Code 128 to Code 39 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Interleaved 2 of 5 (I 2 OF 5) Enable 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) I 2 of 5 Check Character Calculation 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) I 2 of 5 Check Character Transmission 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) I 2 o
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Codabar Start Stop Character Match 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Codabar Check Character Calculation 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Codabar Check Character Transmission 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) Codabar A
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Code 93 Length Control 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) Code 93 Maximum Label Length 50 50 50 50 50 50 50 50 Code 93 Minimum Label Length 2 2 2 2 2 2 2 2 Code 93 Fixed Length 1 8 8 8 8 8 8 8 8 Code 93 Fixed Length 2 14 14 14 14 14 14 14 14 Code 93 Stitching 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1
Table E-2 Aux RS-232 WincorNixdorf Single Cable USB Keybd PC KBW MSI/Plessey Maximum Label Length 16 16 16 16 16 16 MSI/Plessey Minimum Label Length 4 4 4 4 4 4 MSI/Plessey Fixed Length 1 7 7 7 7 7 7 MSI/Plessey Fixed Length 2 8 8 8 8 8 8 MSI/Plessey Stitching 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Standard 2 of 5 Enable 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Standard 2
Table E-2 Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW Standard 2 of 5 Fixed Length 1 10 10 10 10 10 10 10 10 Standard 2 of 5 Fixed Length 2 0 0 0 0 0 0 0 0 Standard 2 of 5 Stitching 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) E-16 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
Appendix F Handheld Data Format Requirements This appendix provides application notes to describe the general format of data that can be accepted by the scanner through the auxiliary port as transmitted from a handheld scanner. Handheld Data Format Requirements General • 9600 bps, 8 data bits, 1 stop bit, no parity. • RTS is used to "bracket" the data received from the handheld: RTS must be asserted high during data transmission, and de-asserted after label transmission is complete.
PSC Handheld Data Format Requirements The following sections describe label transmission formats that are typically observed in factory configurations of PSC handheld scanners. RSS-14 • Prefix must be ASCII characters ‘R4’ • Check character must be included in label • Application identifier “01” must follow the prefix and preceed the base label • Label length excluding prefix characters must be 16 characters.
UPC-A with 5-Digit Supplemental • Number system must be included in label data • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII character 'A' - total length including prefix must be 18 • Example: 'A06099201118712345' UPC-A with Code 128 Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label.
UPC-E with 2-Digit Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII character 'E' - total length including prefix must be 11. • Example: 'E0998875012'. UPC-E with 5-Digit Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct.
EAN-8 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII characters 'FF' - total length including prefix must be 10 • Example: 'FF00210126' EAN-8 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII characters 'FF' - total length including prefix must be 12. • Example: 'FF0021012612'.
EAN-13 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII character 'F'- total length including prefix must be 14 • Example: 'F1101234567891' EAN-13 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct • Supplemental data is appended to base label • Prefix must be an ASCII character 'F'- total length including prefix must be 16 • Example: 'F110123456789112' EAN-13 with 5-Digit Supplemental • Check
Code 39 • Check character must be included in label data. • Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Start and stop characters "*" must be included in label. • Prefix must be an ASCII character '*'. • Example : '**Code 39.TEST*'. Code 39-Pharmacode • Check character must be included in label data.
Codabar • Check character must be included in label data. • Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character '%'. • Start stop character sets must meet the matching requirement set forth by the scanner configuration item Codabar Start Stop Character Match.
MSI/Plessey • Check character must be included in label data. • Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character '@'. • Example: '@144769254'. Code 93 • Prefix must be an ASCII character '&'.
AIM Formats AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted by the scanner as EAN-13. The ']' character must be the first character received in the label transmission from the handheld. The following sections describe the prefix strings and identify what specific label characteristics can be supported.
2-Digit Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']E1'. • length of Supplemental data including prefix must be 5. Total required length is 21 for EAN-13 and 16 for EAN-8. • Examples: addon portion is highlighted data is underlined.
Code 128 Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']C0'. • length of Supplemental data including prefix is variable but must be at least 9. • Examples: addon portion is highlighted data is underlined.
Codabar • Check character must be included in label data. • Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be ASCII characters ']F0'. • Start stop character sets must meet the matching requirement set forth by the scanner configuration item Codabar Start Stop Character Match.
RSS-14 • Prefix must be ASCII characters ']e0'. • Check character must be included in label. • Label length excluding prefix characters must be 14 characters. • Example: ']e001044123456789'. RSS Expanded • Prefix must be ASCII characters ']e0'. • Label length excluding prefix characters must be at least 1 character. Maximum length is the maximum label size supported by the scanner. • Example: ']e001900123456789083103001750'. I 2 of 5 F-14 • Check character must be included in label data.
Code 128 / EAN128 • Prefix must be either ASCII characters ']C0', ']C1' or ']C2'. • Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • If EAN-128 Symbology is Enabled and prefix is ']C1', label will be identified as an EAN128 otherwise it is identified as a Code 128. • A prefix of ']C0' designates that no function code is present in the 1st or 2nd character position.
NOTES F-16 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
NOTES Product Reference Guide F-17
NOTES F-18 Magellan® 2200VS/2200VSΩ and 2300HS/2300HSΩ
ASCII Character Set The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters. Table 1 ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No.
Asia Pacific Italy PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291 PSC S.p.A. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.1 Fax: [39] (0) 39/6859496 Australia Japan PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] 0 (2) 9878 8999 Fax: [61] 0 (2) 9878 8688 PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France Latin America PSC S.A.R.L. LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.