5.
Trouble shooting
① EC (Error Code): If the communication status is not stable, the communication retries and
communication success / failure status are displayed.
② F: Communication failure, Check the communication environment and retry communication.
If you still see communication failure, replace the counter.
③ Communication steps (1~3), Wireless connection steps (1~3)
④ Communication retries (1~2), Wireless connections (1~5)
예) EC F32: Communication retry - 1, Communication steps 3 - failure
EC F15 : Wireless connections - 5, Wireless connection step 1 - failure
Communication failure code and action.
Code
Description
Cause
Action
F11~F15
Wireless connection failure
- System down
- Unstable wireless comm.
environment
- System inspection and
improvement.
- Wireless environment inspection
and improvement
F11~F32
Wireless connection failure
and Data transmission
verification failure
- System down
- Unstable wireless comm.
- product defect
- System inspection and
improvement.
- Wireless environment inspection
and improvement
- Product replacement or make
inquiries
Battery status
※ Depending on the operating environment, such as temperature, there may be a temporary change in status.
6.
Precautions
① When installing or removing in a hot mold, it may cause burns, so work safely at the proper temperature.
② Replace the counter within 1 month if the battery indicator ( ) is blinking.
③ Temporary communication failure may occur depending on the metal wall or the enclosed environment
causing radio interference, in case of continuous communication failure, check and remove the obstacle.
④ Please note that damages due to non-standard environment, carelessness of the user, or arbitrary operation
cannot be serviced.