Installation and Operation Guide
Table Of Contents
- Chapter 1: Introduction
- 1.1 First steps
- 1.2 Service addresses
- 1.3 About this manual
- Chapter 2: Safety
- 2.1 Safety symbols
- 2.2 Information for the system operator
- 2.3 Information for operating personnel
- 2.4 Intended use
- 2.5 Residual risks and safety measures
- Declaration of conformity
- Certifications
- Chapter 3: Technical data
- Chapter 4: System description
- 4.1 VIBCONNECT RF bridge
- 4.2 VIBCONNECT RF sensor unit
- 4.3 VIBCONNECT RF sensor
- Chapter 5: Installation & commissioning
- 5.1 Quick guide
- 5.2 Configuration in OMNITREND
- 5.3 Installation & commissioning of bridge
- 5.4 Installation & commissioning of sensor unit
- 5.5 Installation of sensors
- 5.6 Configuration in OMNITREND (continued)
- 5.7 Installing additional sensor unit
- Chapter 6: Maintenance
- 6.1 Cleaning
- 6.2 System time correction
- 6.3 Installation report
- 6.4 Battery-powered sensor unit
- 6.5 Update
- 6.6 Warranty
- 6.7 Spare parts and accessories
- Chapter 7: Troubleshooting
- Chapter 8: After use
10
VIBCONNECT RF 05.2012
2.5 Residual risks and safety measures
If installed and operated according to the instructions VIBCON-
NECT RF is a safe system. In the event of incorrect operation or use,
the following damage might occur:
• Personal injury
• Damage to the system components or to the machine
• Impaired radio communication (poor reception / transmission)
CAUTION
Risk of injury from falling parts!
When installing a bridge at great height, there is a risk that the
bridge or a tool might fall to the ground, causing injury.
» Cordon off the area immediately below the installation site to
prevent access to the danger area.
» Use fall-arresting equipment.
CAUTION
Risk of injury from electric shock!
When connecting the bridge to the power supply without taking
the necessary safety precautions, there is a risk of energy from
high voltage (220 V).
» The electrical connection must be established by a qualified
electrician.
» The mains voltage must conform to the IEC guidelines.
» An external interface (fuse or switch) must be provided in order
to disconnect the power supply securely.
» Before carrying out any installation, repair or maintenance work
on the bridge, disconnect it from the power supply.
CAUTION
Risk of injury from rotating machine parts!
When installing the sensor unit and the sensors while the machine
is running, there is a risk of serious injury caused by exposed,
moving machine parts.
» Do not remove any guards on the machine.
» Always adhere to the safety instructions for work on running
machinery.