User's Manual

Thermal growth
1
The Thermal growth screen is accessed by tapping "More".
Thermal growth values can be entered only when the type of mounting is either machine feet or bear-
ing or V-shaped support.
To enter any specified thermal growth value at the required feet position, tap the corresponding value
box then proceed to enter the thermal growth value using the onscreen keyboard. Cycle through the
value boxes using or alternatively tapping the desired feet position.
Thermal growth values are activated by tapping "On". When thermal growth values are enabled, the
corresponding machine [1]within the inset at the top-right corner appears in orange. After thermal
growth values have been entered, tap
to proceed.
Coupling properties
Tap either the top or bottom arrow to select desired coupling type.
1
Movement of shaft centerlines associated with or due to a change in machinery temperature between
the idle and operating conditions.
FictionSoft 13