User's Manual
Table Of Contents
User Manual v1.6 8
Printed copies of this document are uncontrolled
5.0 Installation details
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70),
local codes, and the authorities having jurisdiction.
5.1 Parts List
○ Proxy Reader - 1
○ Security Screw – #6 - 32 x 3/8” -- 1 Nos
○ Mounting Screws -- #6-32 x 1” -- 2 Nos
○ Nylon anchor plugs -- #6 Size x 1” -- 2 Nos
5.2 Recommended Infrastructure
○ All cabling and wiring shall be UL Listed and/or UL Recognized
○ All readers shall be powered by UL listed power-limited power supply, or power-
limited output from UL listed control panel
○ There shall be no connections made to the RS-485 interface ( RS485+ and
RS485-) for UL installations
○ Cable Wiegand - 22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N
1299/10C)
○ Cable RS485 - RS485 for 1000m** (4000 ft) 24AWG STP
○ Linear DC PS
○ 6 - 16 V, 1A min.
** Tested in lab conditions up to 115Kbaud