5.0 Installation details
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70),
local codes, and the authorities having jurisdiction.
5.1 Parts List
Proxy Reader - 1
Security Screw #6 - 32 x 3/8” -- 1 Nos
Mounting Screws -- #6-32 x 1” -- 2 Nos
Nylon anchor plugs -- #6 Size x 1” -- 2 Nos
5.2 Recommended Infrastructure
All cabling and wiring shall be UL Listed and/or UL Recognized
All readers shall be powered by UL listed power-limited power supply, or power-
limited output from UL listed control panel
There shall be no connections made to the RS-485 interface ( RS485+ and
RS485-) for UL installations
Cable Wiegand - 22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N
1299/10C)
Cable RS485 - RS485 for 1000m** (4000 ft) 24AWG STP
Linear DC PS
6 - 16 V, 1A min.
** Tested in lab conditions up to 115Kbaud