User's Manual

Product Details
Model Name: Standard Wallbox / PRXY-WW-1.0 / PRXY-WK-1.0
Device Type: RFID reader, 13.56MHz (HF) / 125 KHz (LF) /
Mobile Credential: 2.4GHz (BLE)
 Physical Access control Reader (accessory equipment)
Type of Equipment: Sealed Reader
 Suitable for Indoor use and
 Outdoor use – PRXY-MW-1.0 and PRXY-MK-1.0
Interface Type: Pigtail Cable (11 Core + Drain)
Electrical Rating: 6V - 16V DC, 0.5A, 8W (Max)
Communication Protocol: Wiegand, RS485 (2wire - Half Duplex), BLE, IEEE 802.11b/g/n
Credential Type: 125kHz proximity cards:
- HID® Proximity, Indala®, CasiRusco®, AWID, Farpointe®,
Others
13.56MHz smart cards:
- uTrust, PIV, PIV-I, CAC, TWIC,
- MIFARE Classic, DESFire EV1, PLAID [AS 5185-2010],
- ISO15693 UID, ISO14443A/B UID,
- HID® iClass Card Serial Number (CSN)
BLE: Any bit format (standard or custom) up to 120 bits
Transmission Technology: Wiegand, OSDP, OSDP2 
* Communication via Wiegand was evaluated by UL and serves as the interface between the reader and
panel. Communication via RS485, OSDP or Ethernet was not evaluated by UL.
*IEEE802.11b/g/n communications are used for non-critical operations (OTA, backhaul, etc.).
RF Exposure Information
This device has been tested and meets applicable limits for Radio Frequency (RF) exposure.
This equipment should be installed and operated with minimum distance 20 cm between the radiator &
your body.