User`s guide
28
I've connected one Ethernet cable
to the network switch and an Input
Port and a second Ethernet cable
to a Harmony OpenAir Access
Point and the corresponding
Output Port, but the Channel
Status LED does not turn on.
Confirm that you have an AP Power Over LAN
Module installed between the OpenAir
Access Point and the Power System. The
Harmony OpenAir Access Point must be
connected to an AP Power Over LAN Module
to receive power from the Power System.
The Harmony OpenAir Access Point
is receiving power from the Power
System but I cannot communicate
with the network.
Confirm that you do not have the Access
Point’s 10Base-T crossover adapter
connected to its Ethernet port. The Ethernet
cable provided with the AP Power Over LAN
Module should be connected directly to the
OpenAir Access Point’s Ethernet port.
The Power LED remains amber at
all times.
Try recycling power to the unit. If the
situation persists, contact Proxim Technical
Support for assistance.
The Power LED is red. Try recycling power to the unit. If the
situation persists, contact Proxim Technical
Support for assistance.
Problem Suggested Solution