System information

Configuring Triggers and Alarms
157
“Exclude hardware addresses” combo box—allow you to select the hardware
address.
“Use current protocol filter” checkbox—when selected, allows you to use the
current protocol filter.
Utilization
The Utilization setup dialog lets you set utilization thresholds that will trigger an action.
Utilization trigger level (%) spinbox—allows you to set the percentage of network
bandwidth utilization which you select as the trigger.
Condition section—allows you to choose different ways that the utilization trigger
can be reached. Maximum utilization is the condition when the actual utilization
has reached a user-specified number of times. Average utilization is the condition
when the network’s average utilization is greater than the utilization trigger.
“Averaging period (sec)” spinbox—allows you to set the amount of time, in
seconds, that data will be collected and averaged before a value is considered for
the trigger. Sampling is every second. Values can be from 1 to 100 (seconds).
“Use current protocol filter” checkbox—when selected, allows you to use the
current protocol filter.
Wireless Frame Errors
This dialog lets you set up a trigger for Wireless Frame Errors:
“Percentage of frames with errors” spinbox—Set the percentage of errors that will
trigger an alarm.
“Minimum number of packets (trigger level)” spinboxSet the minimum number
of error packets that will trigger an alarm.