Installation Manual

Tsunami Multipoint Version 1.3 Installation Guide
Safety Instructions
WARNING! IMPORTANT SAFETY INSTRUCTIONS: DO NOT DISCARD!
Review this guide for important installation instructions BEFORE you attempt to install this product.
This product is intended to be installed, used, and maintained by experienced telecommunications
personnel only.
This product has been evaluated to the U.S. and Canadian (Bi-National) Standard for Safety of
Information Technology Equipment, including Electrical Business Equipment, CAN/CSA C22.2,
No. 950-95 * UL 1950, Third Edition, including revisions through revision date March 1, 1998, which
are based on the Fourth Amendment to IEC 950, Second Edition. In addition, this product was also
evaluated to the applicable requirements in UL 1950, Annex NAE.
WARNING! This unit is intended for installation in accordance with Articles 110-18, 110-26, and
110-27 of the United States National Electric Code ANSI/NFPA 70; and per the
applicable Articles in the Canadian Electric Code.
This equipment must be installed in accordance with Article 810 of the United States National
Electrical Code.
Equipment is to be used with, and powered by, the power supplies provided only. A 15-Amp circuit
breaker is required at the power source.
Lightening surge protection is provided by the power supplies included with this product. Do not use
any other devices for this purpose.
WARNING! This equipment is intended to be earthed. Use proper grounding methods. A 10 AWG
earthing conductor at a minimum is to be used for this purpose.
Do not connect or disconnect the power cable to the equipment when the power supply is plugged in
an AC outlet.
Servicing of this product should be performed by trained personnel only. Do not disassemble this
product. By opening or removing any covers you may expose yourself to hazardous energy parts.
Incorrect reassembly of this product can cause a malfunction, and/or electrical shock, when the unit
is subsequently used.
Do not insert any objects of any shape or size inside this product while powered. Objects may contact
hazardous energy parts that could result in a risk of fire or personal injury.
Do not spill any liquids of any kind on or inside this product.
The maximum room ambient temperature (Tmra) for this product is 55°C. Consideration should be
given to installing this equipment in an environment compatible with the Tmra.
Equipment is suitable for mounting on concrete or other noncombustible surface only.
Do not remove or alter the Marking label provided on this product.
The Base Station Unit operates at -48Vdc/1 A. The Subscriber Unit operates at +28Vdc/0.6 A.
About This Book 6