User's Manual Part 2
Table Of Contents
- Chapter 4. System Diagnostics and Operating Tips
 - Appendix A. Initial Settings
 - Appendix B. Installing the Configuration Software and Upgrading Firmware
 - Appendix C. Technical Specifications
- Burst-Rate Limit
 - Downlink/Uplink Throughput
 - Frequency Plans
 - Tx Power
 - Antenna
 - Receiver Sensitivity
 - Maximum Distance Between Base Station and Subscriber Unit
 - System
 - Standards Compliance and Interfaces
 - Configuration and Management
 - Power/Environment Safety
 - Physical Dimension
 - Installation Details
 - Optional Accessories
 
 - Appendix D. Constructing Power and Ethernet Cables
 - Appendix E. Lightning Protection Recommendations
 - Appendix F. Technical Support and Training
 
Tsunami Multipoint Version 1.3 Installation Guide 
Where Should the Protection Units be Located? 
At least one unit should be installed near every outdoor Tsunami unit. General guidelines are: 
▪  Locate protection unit as close to the outdoor Tsunami unit as possible, where the lightning protection 
unit can be securely mounted to a flat surface and grounded properly. Ideally, this should be no 
further than five feet away from the outdoor unit. 
▪  Locate one unit at the roof penetration point, outside, so that the cable immediately enters the 
building after the protection unit. This unit is optional if the distance from the first unit to the roof 
penetration point is relatively short (under 15 feet). 
Installing two units provides the maximum protection against lightning damage to the outdoor Tsunami 
unit and the indoor power adapter, especially if the CAT5 cable length is greater than 15 meters. 
Lightning Protection Specifications 
PolyPhaser 101-1218W-A.1 Data Protector 
Surge:  BellCore 1089 10/100µsec, 100A 
Temperature:  -40°C to +65°C storage/operating +50°C 
Maximum Characteristics Data: 
Turn-on:  +7.0 VDC ± 10% 
Resistance:  1 ohm 
Capacitance:    15 pf Line to Ground, 30 pf Line to Line 
Data Rage:    Up to 100Mbps (100BT) 
Maximum Characteristics DC: 
Turn-on:  ± 68 VDC ± 10% 
Resistance:  0.02 ohm 
User Current:    2A max. 
Size L x W x T:  6.53” x 2.77” x 1.25” 
Appendix E. Lightning Protection Recommendations  C- 
CPN 63179  Issue Date: 01/24/03 
73