Tsunami Multipoint Version 1.3 Installation Guide 
To download locally to an SU: 
1.  From the SU 1.4 or 1.5 Console, select the Download menu. 
2. Select Local Firmware. 
3. From the Look In search field, choose the binary file to be downloaded (PMP_SU_release1-3.mot) 
from the appropriate directory and click Select. The download requires about 2 minutes. Once the 
download is complete, the banner indicating Version 1.3 is displayed. 
If the download does not complete successfully, as indicated by a checksum mismatch or a failure to 
reboot, cycle power to the SU and repeat, starting at step 1. 
Local Download to the BSU 
Use this download method to upgrade BSUs after the SUs have been upgraded to Version 1.3. The BSU 
is upgraded through its Ethernet/Power cable using the BSU 1.4 or 1.5 Console. 
To locally download to the BSU: 
1.  From the BSU 1.4 or 1.5 Console, select the Download menu. 
2. Select Local Firmware. 
3. From the Look In search field, choose the binary file to be downloaded (PMP_BSU_release1-3.mot) 
from the appropriate directory and click Select. 
4.  Once the upgrade is successful, if there were SUs connected to the BSU, they will re-acquire net 
entry. For each SU connection, two messages are displayed: 
º  120 Received NetEntry Request from Eth<SU’s Ethernet address> 
º  121 NetEntry completed: Assigned terminal ID<ID#>, VLAN ID 1, IP<SU’s IP address> 
It normally takes less than a minute and a half for the SUs to re-acquire NetEntry with the BSU from 
the time the local download started. 
5.  If there were no SUs connected to the BSU, after the upgrade succeeds, the version banner is 
displayed with version 20021300, following by three messages: 
º  114 Completed flash sector verification 
º  103 DB check completed 
º  107 Save NV configuration Parameters 
Once the SUs are re-connected to the BSU, expect the same behavior as specified in step 4. 
Appendix B. Installing the Software and Upgrading Firmware  56 
CPN 63179  Issue Date: 01/24/03 