User Manual Part 2

Lynx.GX Installation and Management
Severity Message Description for Alarm Status
CRITICAL Radio Sync The radio is not communicating to the far end.
MAJOR Major relay alarm The major relay is in alarm (a MAJOR alarm condition exists).
MAJOR Link ID mismatch The link security IDs do not match within the last minute.
MAJOR BER 10-3 Error The wireless link BER has exceeded 10
-3
.
MAJOR RF Unit Synth Error The RF UNIT Synthesizer has failed.
MAJOR RF Unit Cable
The RF Unit Cable has been shorted for more than 5 seconds within the
last minute.
MAJOR RF Unit Over Temp RF Unit temperature has exceeded the maximum operating level.
MAJOR RF Unit Low Power The power supplied to the RF Unit is too low.
MAJOR SysBoard Over Temp IDU temperature has exceeded the maximum operating level
MAJOR Loopback Error The internal loopback has measured at least one error.
MAJOR
T1/E1 Port X Input (X is
between 1 and 16)
Port X has the Input Alarm enabled with no data present.
MAJOR IDU IF Synthesizer alarm The IDU IF Synthesizer has failed.
MINOR Minor relay alarm The minor relay is in alarm (a MINOR alarm condition exists).
MINOR RF Unit Comm Error The RF UNIT has lost communication with the IDU.
MINOR SysBoard Fan Error Two or Three IDU Fans have failed.
MINOR FarEnd Alarm There is a major alarm on the far end radio.
MINOR Far End Link Down The wireless link telemetry is down.
WARNING BER 10-6 Error The wireless link BER has exceeded 10
-6
.
WARNING SysBoard Fan Warning The IDU Fan Warning status has changed.
WARNING SysBoard Temp Warning The IDU temperature has gone over the warning level.
WARNING External Input Alarm 1 The External Contact Relay 1 is in the alarm state.
WARNING External Input Alarm 2 The External Contact Relay 2 is in the alarm state.
NORMAL System Reset The radio has reset.
NORMAL Log Reset The log was reset from the web interface or SNMP.
NORMAL Spectrum Analyzer on The Spectrum Analyzer function has been started.
NORMAL Spectrum Analyzer off The Spectrum Analyzer function has been stopped.
NORMAL RF Unit Reset The RF Unit has reset.
Appendix B. Web Interface Windows and Field Descriptions 63