User Manual Part 2
Lynx.GX Installation and Management 
Severity  Message  Description for Alarm Status 
CRITICAL  Radio Sync  The radio is not communicating to the far end. 
MAJOR  Major relay alarm  The major relay is in alarm (a MAJOR alarm condition exists). 
MAJOR  Link ID mismatch  The link security IDs do not match within the last minute. 
MAJOR  BER 10-3 Error  The wireless link BER has exceeded 10
-3
. 
MAJOR  RF Unit Synth Error  The RF UNIT Synthesizer has failed. 
MAJOR  RF Unit Cable 
The RF Unit Cable has been shorted for more than 5 seconds within the 
last minute. 
MAJOR  RF Unit Over Temp  RF Unit temperature has exceeded the maximum operating level. 
MAJOR  RF Unit Low Power  The power supplied to the RF Unit is too low. 
MAJOR  SysBoard Over Temp  IDU temperature has exceeded the maximum operating level 
MAJOR  Loopback Error  The internal loopback has measured at least one error. 
MAJOR 
T1/E1 Port X Input (X is 
between 1 and 16) 
Port X has the Input Alarm enabled with no data present. 
MAJOR  IDU IF Synthesizer alarm  The IDU IF Synthesizer has failed. 
MINOR  Minor relay alarm  The minor relay is in alarm (a MINOR alarm condition exists). 
MINOR  RF Unit Comm Error  The RF UNIT has lost communication with the IDU. 
MINOR  SysBoard Fan Error  Two or Three IDU Fans have failed. 
MINOR  FarEnd Alarm  There is a major alarm on the far end radio. 
MINOR  Far End Link Down  The wireless link telemetry is down. 
WARNING  BER 10-6 Error  The wireless link BER has exceeded 10
-6
.
WARNING  SysBoard Fan Warning  The IDU Fan Warning status has changed. 
WARNING  SysBoard Temp Warning  The IDU temperature has gone over the warning level. 
WARNING  External Input Alarm 1  The External Contact Relay 1 is in the alarm state. 
WARNING  External Input Alarm 2  The External Contact Relay 2 is in the alarm state. 
NORMAL  System Reset  The radio has reset. 
NORMAL  Log Reset  The log was reset from the web interface or SNMP. 
NORMAL  Spectrum Analyzer on  The Spectrum Analyzer function has been started. 
NORMAL  Spectrum Analyzer off  The Spectrum Analyzer function has been stopped. 
NORMAL  RF Unit Reset  The RF Unit has reset. 
Appendix B. Web Interface Windows and Field Descriptions  63 