User Manual Part 2

Lynx.GX Installation and Management
STATUS TAB—VIEWING CURRENT STATUS
To view the current Near and Far status for the selected unit, click the Status tab. You can click the Near or
Far Reset History buttons to clear all data for the corresponding radio, which is useful for resetting the time
stamp, such as after installation. A description of each row follows the figure.
Status Window Field Descriptions
Current BER
Current estimated received bit error rate (near side measures BER from the far end
toward the near end).
Current RSL (~dBm)
Current estimated received signal level in dBm.
Errored Seconds
Number of seconds that incurred at least one bit error since the last reset.
Severely Errored Seconds
Number of seconds that incurred bit errors in excess of BER=10e-3 since the last reset.
Min RSL (~dBm)
Minimum estimated received signal level (in dBm) measured since the last reset.
Min RSL Time Stamp
The last time at which the minimum estimated RSL value was measured.
Max RSL (~dBm)
Maximum estimated received signal level (in dBm) measured since the last reset.
Elapsed Time Since Reset
The amount of time since the last system or history reset.
IDU Temperature (Celsius)
The current internal temperature of the IDU in Celsius.
RF Unit Temperature
(Celsius)
The current internal temperature of the RF Unit in Celsius.
Appendix B. Web Interface Windows and Field Descriptions 59