Installation Manual
Tsunami Multipoint Version 1.3 Installation Guide
Mounting the BSU to a Pole
To mount the BSU to a pole using the attached mounting components:
1. Lash the unit to the pole or use a hoisting rope to keep the unit in place while you mount it. Slide the
two strap clamps over the two sets of 1/2-13x7 1/2 screws and secure the strap clamps using four
#1/2 split lock washers and four 1/2-13 hex nuts (see the following photo).
Figure 13. Strap Clamps Attached and Mounted BSU
2. To adjust the up/down tilt (-10 to +5 degrees), move the top or bottom of the BSU (depending on
how you installed the downtilt/notched bracket assemblies) until the unit is roughly positioned at the
correct angle.
3. Connect the supplied Cat 5 cable to the BSU’s Power and Ethernet port as described in the following
notes. Then screw on the outer ring to secure the cable in place.
Figure 14. BSU’s Power and Ethernet Connector
Chapter 2. Pre-Installation Tasks 21
CPN 63179 Issue Date: 01/24/03