User guide
Installation and Initialization AP-4000MR User Guide
System Requirements
21
Mesh Prerequisites
Before setting up a Mesh network, gather the following information:
PXU (ProximUnify) Prerequisites
Before setting up a PXU Profile, gather the following information:
System Requirements
To begin using an AP, you must have the following minimum requirements:
• A 10Base-T Ethernet or 100Base-TX Fast Ethernet switch or hub or cross-over Ethernet cable
• At least one of the following IEEE 802.11-compliant devices:
– An 802.11a, 802.11b, or 802.11b/g client device
• A computer that is connected to the same IP network as the AP and has one of the following Web browsers installed:
–Microsoft
®
Internet Explorer 6 with Service Pack 1 or later and patch Q323308
–Netscape
®
7.1 or later
Mesh Mode The mode in which the AP will be used. If the AP will be connected directly to the
wired backbone, it should be configured for Mesh Portal mode; if it will connect to the
Portal and backbone wirelessly, it should be configured for Mesh AP mode. If the AP
will not be used in a Mesh network, Mesh Mode can be disabled.
Mesh Interface Number The interface on which the Mesh functionality will be enabled. For Wireless A, the
interface number is 3; for Wireless B, the interface number is 4.
Mesh SSID The name of the Mesh network. The Mesh SSID should be between 1 and 16
characters.
Mesh Security Mode Mesh links may be secured through AES encryption. You may also choose to use
Mesh functionality without security enabled (not recommended).
Mesh AP Shared Secret The password shared between Mesh Access Points when AES is enabled (AES is
enabled by default). This password should be between 6 and 32 characters. The
default password is public.
Parameter Description
Module Parameters Configure the Primary and Secondary Modules parameters
PXU IP Address This field is for IP address of the PXU unit. The default is 0.0.0.0.
Domain Name The field where the domain name will be written.
Shared Secret/ Confirm Shared
Secret
The password is shared by the PXU module and the AP. The same password must
also be configured on the PXU module. The default password is “public.”
Response Time This is the maximum time, in seconds, that the AP should wait for the PXU module to
respond to a request. The range is 1-10 seconds; the default is 3 seconds.
Retransmission The maximum number of times an authentication request may be transmitted. The
range is 0 to 4, the default is 3.
Module Status The status of the PXU Profile