User's Manual Part 1
Configuration MeshMAX 5054 Series User Guide
Configuring the Subscriber Module
81
NOTE: For the 5012-SUI, the aggregate maximum bandwidth shared between input and output is 12 Mbps. If you
attempt to set the input/output bandwidth values so that the total exceeds 12 Mbps, the management interface
will automatically adjust the values to the available aggregate bandwidth of 12 Mbps. For example, the system
default is 6 Mbps for both input and output bandwidths. If you change the input to 8 Mbps, the management
interface will automatically adjust the output to 4 Mbps, for an aggregate bandwidth of 12 Mbps. The values
will not adjust automatically if the total is less than 12 Mbps.
Ethernet
To set the Ethernet speed, duplex mode, and input and output bandwidth limits, click Configure > Interfaces > Ethernet.
You can set the desired speed and transmission mode by clicking on Configuration. Select Auto-duplex (selects the
best transmission mode available when both sides are set to auto-select) from the settings for the type of Ethernet
transmission.
NOTE: The device may not wok, if there is a change in the configuration.
SNMP Parameters
Click Configure > SNMP to enable or disable trap groups, and to configure the SNMP management stations to which the
Subscriber unit sends system traps. See “Trap Groups” in the MeshMAX 5054 Subscriber Unit/MeshMAX 5054
Subscriber Unit/MeshMAX 5054 Subscriber Unit/Tsunami MP.11/QB.11 Reference Manual for a list of the system traps.
• Trap Groups: You can enable or disable different types of traps in the system. By default, all traps are enabled.
• Trap Host Table: This table shows the SNMP management stations to which the Subscriber unit sends system traps.