User's Manual Part 1

Installation and Initialization MeshMAX 5054 Series User Guide
30
Reboot and Reset Functionality for MeshMAX
Press the Reload button (on the side of the power injector) to intiate the Reload/Reset functionality. You may have to use
the end of a pin or paperclip to press the button.
Reboot and Reset Functionality for Mesh and Access Point Module
If the Reload button is pressed for 5 to 10 seconds and then released, then Mesh and Access Point module moves to the
bootloader state. If Reload button is pressed beyond 10 seconds, then the Mesh and Access Point module’s Reload
functionality is ignored.
Reboot and Reset Functionality for Subscriber Module
If the Reload button is pressed for 20 seconds and above, then the Subscriber module moves to reload state. If the
Reload button is pressed for 10 to 20 sconds and released, then none of the operation is performed and the Reload
button is aborted.
NOTE: Bootloader will display allevents to the serial console, which will guide user to perform the Reload functionality.