User's Manual

Troubleshooting
# Architecture: MIPS 7660
# Creation: 10-Aug-2009 (IST) 08:16:14 PM
#################################################|
Username: admin
Password:
This process may take up to 90 seconds.
2. Enter the CLI Username and password. By default username is admin and password is public. The terminal displays a
welcome message and then the CLI Prompt. Enter ‘show ip’ as shown below:
System Name> show ip
The following Ethernet IP information is displayed:
// Ethernet IP CONFIGURATION //
INDEX 1
IP Address : 10.0.0.1
Mask : 255.255.255.0
Address Type : static
// IP Gateway Configuration //
Gateway IP Address : 169.254.128.1
3. Change the IP address and other network values using the following CLI commands (use your own IP address and
Subnet mask).
System Name> enable
System Name# configure
System Name(config)#network
System Name(config-net)# ip
System Name(config-net-ip)# ethernet-ip-table
System Name(config-net-ip-etherip)# rowedit 1 ipaddress <ipaddress>
System Name(config-net-ip-etherip)# rowedit 1 mask <subnet mask>
System Name(config-net-ip-etherip)# rowedit 1 address-type <Address Type>
System Name(config-net-ip)# default-gateway <IP Gateway>
System Name(config-net-ip-etherip)#exit
System Name(config-net-ip)#exit
System Name(config-net)#exit
System Name(config)# commit 1
System Name(config)# reboot 1
4. After the device reboots, verify the new IP address by reconnecting to the CLI. Alternatively, you can ping the device
from a network computer to confirm that the new IP address has taken effect.
When a proper IP address is set, use HTTP interface or Telnet to configure the rest of the operating parameters of the
device.
8.10 Spectrum Analyzer
The ultimate way to discover whether there is a source of interference is to use a Spectrum Analyzer. Usually, the antenna is
connected to the analyzer when measuring. By turning the antenna 360°, one can check the direction of the interference. The
analyzer will also display the frequencies and the level of signal is detected. Proxim recommends performing the test at various
locations to find the most ideal location for the equipment.
Tsunami® 8100 Series - Software Management Guide 217