User's Manual

Management
Figure 6-23 Reset to Factory Defaults
Click OK, if you wish to proceed with factory reset, else click Cancel.
6.7 Convert QB to MP
The Convert QB to MP tab lets you convert a QB to SU so that the converted device can connect to a BSU and operate as a
regular SU.
This feature is applicable only to,
Tsunami® QB-8100-EPA which converts to a Tsunami® MP-8100-SUA, and
Tsunami® QB-8150-EPR which converts to a Tsunami® MP-8150-SUR
You can convert a QB to SU mode by using two methods:
Method 1: Web Interface
Method 2: Load a SU config file (retrieved from another SU) onto the QB device and then reboot.
: Even after conversion from QB to MP, the device description still shows as QB.
To convert a QB to SU using Web Interface, do the following:
1. Navigate to MANAGEMENT > Convert QB to MP. The Convert QB to MP screen appears:
Figure 6-24 Convert QB to MP
2. Click OK.
3. Reboot the device for the changes to take effect.
:
• A QB after converting to SU will function in SU mode only. It will accept only MP firmware for upgrade.
• The version of the firmware being upgraded to should be 2.4.0 or later. If earlier version of the firmware is loaded, the
device will reset to factory default upon initialization and operate in QB mode.
• When upgrading a converted device from Bootloader, it must be done using a QB image, as the device is licensed as
QB.
• The conversion of the device from QB to SU requires a reboot.
Tsunami® 8100 Series - Software Management Guide 171