User Manual

INSTALLATION AND MAINTENANCE MANUAL
LYNX.sc E1 FAMILY
SPREAD SPECTRUM RADIOS
OCTOBER 1998
SECTION 4: TROUBLESHOOTING PAGE 4-1
4. Troubleshooting
4.1 Regular Maintenance
The LYNX.sc radios do not require any regular maintenance, however, it is prudent to monitor the
radio link at regular intervals to assure that the link conditions are not changing. When visiting a
radio site for maintenance, the following items may be checked and their results recorded:
RSL Voltage
PWR Voltage
Far-end RSL Voltage
Alarm conditions
Verify radio has adequate ventilation
If any alarm conditions exist, they should be recorded, and troubleshooting procedures from this
Section of the manual should be followed.