User Manual
INSTALLATION AND MAINTENANCE MANUAL
LYNX.sc E1 FAMILY
SPREAD SPECTRUM RADIOS
OCTOBER 1998
PAGE 3-44 SECTION 3: INSTALLATION & ADJUSTMENTS
Figure 3-19: RJ-11 Orderwire Telephone Connection
2. Using a standard RJ-11 telephone cable, connect a standard electronic telephone (a
touch tone phone, complete with dialer; a handset by itself will not work) to the Orderwire
connector on the LYNX.sc front panel. This connector is wired identically to a standard
two-wire telephone jack, see Figure 3-19 for details.
3. With a telephone connected to each LYNX.sc terminal on opposite ends of the link, either
telephone can be used to “dial-up” the far-end location. Simply pick up the handset of the
near-end telephone and dial the two-digit address of the far-end LYNX.sc terminal. The
far-end terminal’s internal ringer and the connected telephone will ring, and if answered,
two-way full-duplex voice communication is established.
If using the Orderwire or Network management functions, all
LYNX.sc radios connected must have unique address settings
(telephone numbers).
The orderwire address is set by two rotary switches on the rear
panel of the LYNX.sc radio. Use as small screwdriver to select
the orderwire address (01 through 99).