User Manual

INSTALLATION AND MAINTENANCE MANUAL
LYNX.sc E1 FAMILY
SPREAD SPECTRUM RADIOS
OCTOBER 1998
PAGE 5-4 SECTION 5: APPENDICES
Shaded switch
p
ositions are factor
y
default
12345678
SW1
1
000000000
1
Loss of Input Data Alarm
0 Enable
1 Disable
3
Loopback Test Source
0 Internal
1 External
4
Error LED Latch
0 Enable
1 Disable (Flash)
5
Rx AIS Output
0 Enable
1 Disable
Diagnostics Port
7
TBOS 0
Craft 1
Aux Data Port
8
Bridged (TBOS) 0
Enabled (Clear) 1
1234
SW2
1
00000
1
CEPT-1 Ground
0 Floating
1 Grounded
12345678
SW3
1xx
0000000xx
12
Spreading Code
0 0 Code 1
0 1 Code 2
1 0 Code 3
1 1 Code 4
Frequency Xmtr Rcvr
78
A1 2410 2453 0 0
A2 2453 2410 0 1
B1 2430 2473 1 0
B2 2473 2430 1 1
Table B-1: LYNX.sc 2.4 GHz 1xE1 Switch Settings