User's Manual

Table Of Contents
Temp : 43.0C
RX_PWR(dBm): -55
T/R value : -1010.000
Tx f band : 1918419687
RSSI (dBm) : -54.8
ok - status of command sh rad st
ok - status of command sh hsi delayed
xxx\#run fd - records factory default configuration (does not change settings)
xxx\#run w0 - records saved configuration of device after reset
xxx\#run w1 - records saved configuration of device from w1(-3) position
xxx\#run auto - automatic update of configuration (run w0) after 6 minutes (enable
timeout) since last adjusting command (turning-off “run noauto”, or
“exit”).
xxx\#write w0 - Saves configuration with IP settings
xxx\#write w1 - Save configuration without IP settings
Tsunami™ GX800 Installation and Management Guide 72