User's Manual

Table Of Contents
RADIO-Status
Alarms(00) : 00 - hexadecimal dump of ODU alarms (00 = OK)
Temp : 50.0C - temperature of ODU (-25 up to 55 C ok)
RX_PWR(dBm): -46 - received level of signal (higher then -70 is OK)
Subband : A
MW band : 11.00 GHz
Band level : L
SDH/PDH : T
Side-r : L
T/R value : 490.00MHz - distance Rx and Tx frequency
Tx f band : 10700-10890MHz - valid setting of Tx frequency
Ok
xxx\#sh rad atpc
atpc : off - status of automatic proceeding of output power (on/off - turned-on/turned-
off)
cur. txp.: 5dBm - current sent power
max txp. : 5dBm - maximal (adjusted - “set rad txp xxx”) transmitting power
cur. rxl.: -55dBm - current received level of signal
min rxl. : -60dBm - set (“set rad atpc rxl xxx”) maximal level of signal to which it will regulate
(+2dBm hysteresis)
The key command for local device is “sh local” and analogical command for opposite device is
“sh remote”.
xxx\#sh local
ocal status : ok
LOCAL RADIO
Temperature : 45C - ODU temperature
Tx frequency : 18490.000MHz - transmit frequency
Current Rxl. : -51dBm - received power
ATPC Rx level: -60dBm - adjusted minimal level of signal for ATPC
Current Txp. : 5dBm - current transmit power
Alarm (00) : 00 - hexadecimal dump of ODU alarms (00 = ok)
LOCAL IDU
Temperature : 40C - IDU temperature
MSE : -35.1dB - distance of dots in v I/Q diagram from ideal location (smaller = better)
Modem sync(1) : 1 - status of synchronization (1 = OK, 0 = loss, another number = code of error)
Alarm (1d) : 1d - hexadecimal dump ODU alarms (1d = OK)
Error seconds : 0 - number of error seconds on rfi PBPS
HSI interface : E3 - type of inserted modulus
SETTING:-| |-STATUS
... list of report follows as in dump “sh alarm
To switch between the Transmit /Receive (T/R) spacing for ODU units, use the following
command:
xxx\#set radio tr high/low
For administering the device, use the following commands:
xxx\#delayed 30 sh rad stat - it executes command “sh rad stat” after 30 second of waiting
sleeping 30 seconds
running command "sh rad st"
ok
xxx\#sh his delayed
Wed, 01.10.2008 11:37:57 - sh rad st - date of record and command
RADIO-Status - dump of command
Alarms(00) : 00
Tsunami™ GX800 Installation and Management Guide 71