User's Manual
Table Of Contents
- Chapter 1 - Introduction
- Chapter 2 – Hardware Overview
- Chapter 3 – Installation and Initialization
- Chapter 4 - Commissioning
- Introduction
- Access Rights
- Restore Defaults
- Configure, Manage and Monitor using Web Browser
- General Screen
- IP Address Setup
- Dual License - Design Type Setup
- Frequency, Modulation and ATPC Setup
- Ethernet Advanced Configuration
- Data Rate Settings for Connected User Interfaces
- Save Configured Parameters
- BER Test – GX800 Link and User Lines Verification
- Analysis of Interference in GX800 link
- Firmware Upgrade, License Upgrade
- Alarms
- SNMP Settings
- IP Management
- Chapter 5 – Troubleshooting
- Chapter 6 - Technical Parameters
- Chapter 7 - Appendix
LANB1
frm tx : 366 - number of sent LAN frames
frm rx : 953 - number of received LAN frames
frm err : 0 - number of faulty LAN frames
LANB2
frm tx : 0
frm rx : 0
frm err : 0
WANB1
frm tx : 953 - number of sent WAN frames
frm rx : 366 - number of received WAN frames
frm err : 0 - number of faulty WAN frames
xxx\#sh ber
status : sync random - synchronization status
conf speed:100Mbps - adjusted speed
act. speed: 34.6Mbps - actual measured speed
tx pattern: random - adjusted succession
bit count : 1.36692e+10 - number of received bits
err count : 0 - number of received error bytes
sync count: 1 - number of synchronizations
ber : 0 - bit error rate
tle : 385s - time between errors
tbe : 0s - time when the last error occurred
efs : 385s - time during which device works without error
ers : 3s - time during which device works with error (second control)
With Best tester, it is possible to set both the rfi direction (“set ber speed xxx” - attention, it has
the lowest priority; for right function it is necessary to decrease Ethernet capacity), and HSI
direction (“set hsi e1 chxx ber”, “set hsi e2 chxx ber”) and control the given data path. It is
possible to combine the Ber tester with loop backs for verification of the right function of data
paths (“set e 1 chx loop”, “set hsi loop”, ...)
For loop backs, it is needed to look for possible embedded Ethernet.
Counter and also ber tester is possible to delete (“cle cou” , “cle lancou”, “cle ber”).
The device status can be viewed with commands “sh st lan”, “sh st mux”, “sh st system”, “sh
modem”, “sh radio stat”, “sh radio atpc”.
xxx\#sh st lan
LANA1 - Gigabit user data port
link : none - detection link
aneg : on - setting of automatic speed/duplex detection
duplex : not resolved - actual (identified) duplex (not resolved/half/full)
speed : not resolved - actual (identified ) speed (not resolved/1000m/100m/10m)
LANA2 - port of internal switch interconnection
link : ok
aneg : off
duplex : full
speed : 100m
LANB1 - 100Mbit management port
link : ok
aneg : on
duplex : full
speed : 100m
LANB2 - port of internal switch interconnection
switch : off - (on/off) enabled/denied switch interconnection
Tsunami™ GX800 Installation and Management Guide 69